IMPORTANT SAFETy INFORMATION
NOTICE
Allow a minimum clearance of 1" (25 mm) along the sides
and rear of unit for proper ventilation. Do not block or
cover any cabinet venting.
Do not cover racks or any other part of oven with metal foil.
Airflow restriction will cause oven to overheat.
Do not lay unit on front or back side. Damage to unit could
occur.

MODEL DESCRIPTION

All Models

Ovention
matchbox
Ovens are designed to provide unequaled
®
®
flexibility in both kitchen and front-of-the-house installations. The
variety of menu options, small footprint, low heat escape, and
hood-less installation make the matchbox Oven a single solution
alternative to multiple pieces of cooking equipment.
Each matchbox Oven is equipped with dedicated upper and lower
heating elements and air blowers. The air blowers direct heated
air through upper and lower jet plates inside the oven chamber,
above and below the food. a slider assembly consisting of two
separate cooking surfaces moves between the left platform, oven
chamber, and right platform through the use of a drive motor and
gear wheel. When one cooking surface is in the oven chamber,
the other is on its corresponding platform awaiting the next food
item.
Left Platform
Cooking Rack
Slider Assembly
(Left End Cap)
Oven Door
All manuals and user guides at all-guides.com
Oven Chamber
Main Disconnect
Switch
Touchscreens
USB Port
Standby Switch
model Description (model m1718 shown)
4
NOTICE
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch finish of unit, marring its
appearance and making it susceptible to soil accumulation.
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Operator controls consist of two touchscreens (one for each
cooking surface), a Standby switch, and a main Disconnect switch
(model m1718 only). Two removable crumb trays, one below each
platform, allow for easy cleanup. a USB port allows the uploading
of pre-programmed menu items, installation of software updates,
and opportunity for service diagnostics. a 6' (1829 mm) cord and
plug set is standard.