LEVELING
With platter off, level the scale by adjusting the feet until
the scale is stable and the bubble is centered inside the
reference circle. Level is located on the display bracket.
(See Figure 1)
PC AND POWER CONNECTIONS
1. Choose one method of connecting the scale to your
PC: USB or RS232. (See Figure 2)
USB Cable
• Preferred method is USB if supported in carrier or
shipping software.
• USB connection must be used if scale is to communicate
with multiple carrier or shipping software programs.
CAUTION! DO NOT connect both USB and RS232
cables at the same time.
2. Turn the scale over and make the PC connections as
follows:
USB
• Plug small end of USB cable into the scale
connector port marked "USB." (See Figure 3)
• Plug large end of the USB cable into the PC. A direct
connection to the computer is required. Do not use
a USB hub.
NOTE: The scale is adequately powered by the
USB port so the Power Supply is not needed with
a USB connection.
1
2
I 0 I 0 I
DISPLAY
DISPLAY
RS232
PAGE 2 OF 18
Figure 1
Correct Level
Incorrect
Figure 2
RS232 Cable
Figure 3
PC Connectors
USB/PWR
USB
SET UP
RS232
• Plug the small end of the RS232 cable into the scale
connector port marked "RS232." Connect the large
end of the RS232 cable into the PC port (generally
labeled COM 1, COM A or IOIOI). (See Figure 4)
• Plug large end of the USB cable into the power
supply. Plug small end into USB connector. Plug
power supply into AC outlet.
NOTE: If you plugged the RS232 cable into the
incorrect PC port, turn off the computer, then
change ports and restart your computer.
1
2
DISPLAY
DISPLAY
RS-232
Power supply is required for RS232 connection.
GEOCAL LOCATION
The very first time the scale is powered up, if the display
shows "0•0", skip to Software Configuration. If the
display shows "GEo_Code" (See Figure 5), then enter the
GeoCal™ Code as follows:
GEO Code:
Language/Units:
Manifest SW:
SW Num: 30099478 Ver 0.00.0001
• Choose the code from the GeoCal™ Location Codes
chart on page 3 that best matches your location.
• With GEO Code box highlighted, press
scroll to that number. Numbers will repeat.
• Use
key to highlight Language/Units if enabled.
Press the
or
Items will repeat. Do the same for the Manifest SW if
enabled.
• Press
key to highlight EXIT and press
will reboot.
PC Connectors
I 0 I 0 I
RS232
USB/PWR
USB
Initial Setup
15
English-1b
Standard
Exit
key to scroll to the proper selection.
Figure 4
AC
Outlet
Figure 5
or
to
. Scale