System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on the
AC output receptacles. The system ground is connected to the
AC neutral wire (the neutral is bonded to the generator frame).
Special Requirements
There may be Federal or State regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.
This generator is not intended to be used at a construction
site or similar activity as defined by NFPA 70-2017 (NEC)
section 590.6.
To Restore Home Power Using a Listed
Transfer Switch
Connections to your home's electrical system must use a
listed* transfer switch installed by a licensed electrician.
The connection must isolate the generator power from
the utility power and comply with all applicable laws and
electrical codes. Power your home with a 30 Amp transfer
switch system.
120/240V
Outlet
Typical Indoor Items
To Restore Power Using Extension Cords
Transfer
—
Switch
120V
OUTLET
Equipment Description
1. Only use grounded cords marked for outdoor use
rated for your loads.
To provide power using
extension cords
Total
Minimum Gauge, Outdoor Rated
Amperage
Up to 50 FT (15 M)
Up to 13A
16
Up to 15A
14
Up to 20A
12
Up to 30A
10
2. Follow cord safety instructions.
3. Install carbon monoxide alarm(s).
4. When operating generator with extension cords, make
sure it is located in an open, outdoor area, at least 20
ft. (6.1 m.) from occupied spaces with exhaust pointed
away.
5. Extension cords running directly into home, powering
indoor items IS NOT RECOMMENDED.
DANGER! Engine exhaust contains carbon
monoxide, a poisonous gas that will kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
• Extension cords running directly into the home
increase your risk of carbon monoxide poisoning
through openings.
• If an extension cord running directly into the home is
used to power indoor items, the operator recognizes
that this increases the risk of CO poisoning to people
inside the home and assumes that risk.
6. Install a listed* transfer switch as soon as possible
if generator will be used to provide home power
restoration.
* Certified by a Nationally Recognized Testing Laboratory
that the product complies to appropriate product safety test
standards.
Up to 100 FT (30 M)
14
12
10
8
EN3