Descargar Imprimir esta página

Safety Precaution; Installation Instructions - Hotpoint Ariston AH 90 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
General
General
GB
Carefully read the following important information
regarding installation safety and maintenance.
Keep this information booklet accessible for further
consultations.
The appliance has been designed for use in the ducting
version (air exhaust to the outside – Fig.1B), filtering
version (air circulation on the inside – Fig.1A).

Safety precaution

1. Take care when the cooker hood is operating
simultaneously with an open fireplace or burner that
depend on the air in the environment and are supplied by
other than electrical energy, as the cooker hood removes
the air from the environment which a burner or fireplace
need for combustion.
The negative pressure in the environment must not
exceed 4Pa (4x10-5 bar). Provide adequate ventilation
in the environment for a safe operation of the cooker
hood. Follow the local laws applicable for external air
evacuation.
Before connecting the model to the electricity net-
work:
- control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable.
If in doubt ask a qualified electrician figure 1C.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may
be obtained direct from the manufacturer or from the
Technical Assistance Centre.
- This device must be connected to the supply network
through either a plug fused 3A or hardwired to a 2 fase
spur protected by 3A fuse.
2. Warning!
In certain circumstances electrical appliances may
be a danger hazard.
A) Do not check the status of the filters while the
cooker hood is operating
B) Do not touch bulbs or adjacent areas, during
or straight after prolonged use of the lighting
installation.
C) Flambè cooking is prohibited underneath the
cooker hood
D) Avoid free flame, as it is damaging for the filters
and a fire hazard
E) Constantly check food frying to avoid that the
overheated oil may become a fire hazard
F) Disconnect the electrical plug prior to any mainte-
nance.
G) This appliance is not intended for use by young
32
All manuals and user guides at all-guides.com
children or infirm persons without supervision
H) Young children should be supervised to ensure
they do not play with the appliance
I) There shall be adequate ventilation of the room
when the rangehood is used at the same time as ap-
pliances burning gas or other fuels
L) There is a risk of fire if cleaning is not carried out
in accordance with the instructions
This appliance conforms to the European Directive
EC/2002/96, Waste Electrical and Electronic Equipment
(WEEE).
By making sure that this appliance is disposed of in a
suitable manner, the user is helping to prevent potential
damage to the environment or to public health.
The symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to a
suitable electric and electronic appliance recycling
collection point. Follow local guidelines when disposing
of waste. zFor more information on the treatment, re-use
and recycling of this product, please contact your local
authority, domestic waste collection service or the shop
where the appliance was purchased.

Installation instructions

Assembly and electrical connections must be carried out
by specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load
indicated on the description label.
Where a plug is provided, the cooker hood must be
installed in order that the plug is easily accessible.
An omnipolar switch with a minimum opening of 3mm
between contacts, in line with the electrical load and
local standards, must be placed between the appliance
and the network in the case of direct connection to the
electrical network.
• The minimum distance between the support surfaces
of the cooking pots on the cooker top and the lowest part
of the cooker hood must be at least 65 cm.
If a connection tube composed of two parts is used, the
upper part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating
fumes from other appliances generated by other than an

Publicidad

loading