Translation of the original instructions
BA000655 - 01/2011 (Rev. A)
SA-PROFIBUS-DP
Safety Instructions
Only trained professional electricians may in-
stall, startup, modify, and retrofit this equip-
ment!
Disconnect supply voltage to the equipment /
system prior to starting any work! If installation
or system errors occur, line voltage may be pre-
sent at the control circuit in devices without DC
isolation!
Observe all electrical safety regulations issued
by the appropriate technical authorities or the
trade association.
Opening the housing or any other manipulation
will void the warranty.
Attention!
If the device has been subjected to improper or
incorrect use it must no longer be used, and the
guarantee loses its validity. Impermissible con-
ditions include:
strong mechanical stress, for example through a
fall, or voltages, currents, temperatures or hu-
midity outside of the specifications.
Before starting up your machine/plant for the
first time, please be sure to check all the safety
functions according to valid regulations, and
observe the specified test cycles for safety
equipment.
Attention!
Perform the following precautionary steps prior
to installation, assembly, or disassembly:
1.
Disconnect supply voltage to the equip-
ment / system prior to starting any work!
2.
Lockout/tag the equipment / system to
prevent accidental activation!
3.
Confirm that no voltage is present!
4.
Ground the phases and short to ground!
5.
Protect against adjacent live components
using guards and barriers!
Attention!
Limited contact protection!
Protection type according to EN 60529
Housing/terminals: IP 40 / IP 20
Finger-proof acc. to EN 50247
All manuals and user guides at all-guides.com
PROFIBUS-DP Bus Coupling Module
in the samos modular safety system
•
Diagnosis via field bus
•
PROFIBUS-DP slave, no safe field bus
•
Baud rate adjustable up to 12 Mbit/s
•
Bus address adjustable (00-99)
•
Minimal 4 bytes diagnosis data transmitted
•
4 Outputs to set inputs of the system
•
LEDs for displaying the status of the module
Device style
SA-PROFIBUS-DP-A with screw-type terminals pluggable
SA-PROFIBUS-DP-C with spring-type terminals pluggable
Proper Use
These devices are bus coupling modules in the
samos
purpose in the
system as components of safety equipment on machines intended to protect per-
sons, material and plant.
Device Description
The bus coupling module can only be used together with other modules in the
It collect diagnosis data of the system and supply the data via PROFIBUS-DP.
The field bus is not safe operated.
Transmit data direct to the samos system via field bus is not possible. However it is possible to control the
inputs of the system with the device outputs.
The bus address is adjustable with rotary switches ( x1 / x10). To set the address switch off / on the
power supply.
Mount the device on the right side of the system. No further modules can be mounted.
Installation
•
The devices must be installed in an enclosure with at least IP54 protection.
•
The devices must be installed on a mounting rail (EN 50022-35).
•
The mounting rail must be connected to protective earth (PE).
•
The system and the system inputs must always be powered by a common power supply unit.
•
The external power supply unit must comply with the regulations for safety and protection
extra low voltage systems (SELV, PELV acc. to IEC 60536) and EN 50178 (Electronic Equip-
ment for Use in Power Installations).
Notes
•
The power supply of the device is conducted via the
terminals are on the device.
•
The device must be operated within the limits specified in the technical data.
For installation and operation of the devices observe the national instructions and instructions
issued by safety authorities.
Observe the instructions and information in this manual in order to ensure correct configuring,
startup and operation of the device.
samos
manual English, order no.: R1.180.0290.0
Download the GSD file from info service
samos
system. They must only be used for their intended
samos
system bus. No power supply
www.wieland-electric.com
samos
system.
5