MAXIMUM WATER TEMPERATURE ADJUSTMENT
NOTE: Prior to adjustment, make
sure the handle is in the maximum
hot position.
S
Remove the handle and bonnet.
Turn the water to the maximum
temperature by pushing the valve
stem up and turning clockwise.
S
Mark the current position of the
temperature stop tab (top edge)
on the mounting nut with a marker
or pencil. Lift both the indexer and
the disc just enough to clear the
splines and allow rotation.
NOTE: Each spline notch repre-
sents an average 9.5_ F (5.3_ C).
temperature change.
S
Turn the indexer, disc, and valve
stem counterclockwise until the
desired cooler water temperature
is achieved. Reinstall the indexer
and the disc to the valve, making
sure the disc is snapped fully into
the indexer.
S
Turn off the water by pulling the
valve stem down. Reinstall the
bonnet and handle.
CALL US FOR HELP
Questions? Problems? First review the installation instructions to ensure
correct installation. For additional assistance, call our Customer Service
Department for direct help. You may also contact us at our web site listed
below.
In the U.S.A., call 1 800 4 KOHLER
In Mexico, call 001 877 680 1310
In Canada, call 1 800 964 5590
Kohler Co., Kohler, WI U.S.A.
Handle
Stop Tab
Mounting Nut
www.kohler.com
3
Bonnet
Valve Stem
Disc
Splines
1002236 2