information about creating an optimum humidity control
environment, contact EnviroBoss at 800-932-3030.
Set up drain hose
The EB240 condensate pump connects to a plastic
drainage hose that is located in the pocket on the side of
the unit. This hose is equipped with a quick-connect
fitting for quick attachment to the provided drain hose.
Unwrap the entire hose and place the unattached end in
a sink, drain, bucket or outdoors – anywhere that water
can drain out safely. If you use a bucket or other
container for water collection, check it regularly to
prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled on the unit and do
not place the end of the hose higher than 20 ft. (6 m)
above the bottom of the unit. Also check for kinks or
other obstructions that might restrict the flow of water.
FIG. A: FRONT
FIG. A: FRONT
FIG. C: POWER
ATTACHMENT POINT
07-02184B EB240
Humid air inlet
filter.
Integrated handle.
Folds for storage.
Process (dehumidified)
air outlet. May be used
with standard 12 in.
rigid or layflat ducting.
Power cord socket.
Product label and
serial number.
Obstructions may cause a water backup and result in
overflows.
Plug in electrical cord
The EB240 dehumidifier should be plugged into a
GFCI-protected 115 volt outlet rated for at least 15 amps.
Remove the cord from its storage pocket and uncoil it.
Always plug the cord firmly into the unit first, and then
plug the other end into a suitable outlet.
Turn the unit on
The control panel on the EB240 dehumidifier has a
display and a touchpad with four keys. Press the
ON/OFF to turn the unit on.
FIG. B: BACK
Control panel.
Back panel. Remove to
access the pump.