Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis
procedure and no user intervention is required.
Once the self-diagnosis is complete, the display will
switch to normal display mode.
HUMIDISTAT
INLET 00°C / INLET 00%
The first line of the display shows that the unit is in
humidistate mode. The second line of the display
alternates between inlet temperature and inlet humidity.
User Settings Menu
A number of settings may be changed by the user.
System information can also be displayed. These items
are accessed by pressing
press of the key will display the next parameter. When
you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
Error messages
If the EB240 onboard diagnostics discover a problem,
the unit will display an error message. See "Error
Messages" for an explanation of each message.

Control Panel Guide

ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
CONTROL PANEL
DISPLAY
ON/OFF
ON/OFF
Press and release to turn unit on
or off.
DISPLAY MENU
Press to select next item in menu. Menu
item will show in display.
MENU SELECTION /
Press to toggle or select values in menu
UP KEY
displayed.
PURGE PUMP
Press and release to start purge. Display
will count down seconds remaining
07-02184B EB240
until purge is complete.
DISPLAY MENU. Each
PURGE
MENU
DISPLAY
SELECTION/
MENU
UP KEY
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation
immediately.
DISPLAY MENU. Press to cycle through the display
of additional dehumidifier conditions and User Settings.
To return to the main menu, press the ON/OFF key
once.
MENU SELECTION. Press to change the values of
the "User Defined" settings. The MENU SELECTION key
acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(below) for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown. NOTE: During normal
operation, the pump purges automatically.
Changing settings and viewing system information
A number of settings may be changed by the user.
System information is also available. These items are
accessed by pressing
of the key will display the next parameter (see list
below). When you reach the parameter you wish to
adjust, press
MENU SELECTION to increase the
value. Press
DISPLAY MENU again to accept the
setting and re-start the display cycle.
3
DISPLAY MENU. Each press
Drain hose location.