Operation
AutoSense Gap
Sensor Adjustment
Dump Mode
Sample Printout
42
All manuals and user guides at all-guides.com
To activate the AutoSense feature, first place
the power switch in the OFF (0) position. Load
labels into the printer (do not use the dispenser),
then press and hold the FEED Control
while placing the power switch in the ON
(1) position. Release the FEED Control when
the printer starts feeding labels. The printer will
advance 3-4 labels while performing the
adjustment. When the adjustment is complete,
a status summary label will be printed and the
printer will be placed in Diagnostic Dump
mode. Tap the FEED Control once to switch
the printer back to normal operation. If the
indicator continues to glow ORANGE or
switches to RED, refer to Appendix A for
troubleshooting information.
980101-100 Rev.A