Technical Characteristics - tau K125M Guía Para La Instalación

Ocultar thumbs Ver también para K125M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CONTROL BOARD FOR T-ONE5B GEARMOTOR
• MICROPROCESSOR-CONTROLLED LOGIC
• INPUT STATUS LED'S
• LINE INPUT FUSE
• "PEDESTRIAN GATE" FUNCTION
• BUILT-IN FLASHING LIGHT CIRCUIT
• 433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
• BATTERY CHARGER BOARD (INTEGRATED)
• BATTERY CONNECTOR
• ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
• ADJUSTABLE DECELERATION
• DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
• EN COMPLIANT AND CERTIFIABLE UP TO 500 KG LEAF
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables.
TESTING
When you have completed the connection:
• All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off
only when the controls to which they are associated are operated.
• All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The light up
only when the controls to which they are associated are operated. Except for the DL3 diagnostics
led which must always be on.

TECHNICAL CHARACTERISTICS

Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F3 - 5x20)
Fast acting fuse for protection of battery (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
Box protected to
CONNECTIONS TO TERMINAL BOARD
Terminals
Function
POWER
FS1 - FS2
SUPPLY
SENSITIVE
1 - 3
EDGE
Description
board supply input 13,5 Vac – Powered by the toroidal transformer
housed in the T-ONE5B motor and protected by a fuse (F 6,3A) on
the 230 Vac power supply.
SENSITIVE EDGE input (resistive sensitive edge or fixed safety
edge); Works only when the gate is opening; temporarily stops the
gate and partially closes it by about 20 cm in order to allow the ob-
stacle to be removed. 1= SENSITIVE EDGE, 3= COMMON.
If a resistive sensitive edge is connected, set dip-switch no.
9 to ON;
If a fixed safety edge with NC contact is connected, set dip-
switch no. 9 to OFF.
K125M
13,5V AC - 50 Hz
50 W - 18V DC
F 16 A
F 10 A
F 2 A
F 10 A
18V DC
18V DC
5V DC
-20 °C ÷ +55 °C
IP 44
15

Publicidad

Tabla de contenido
loading

Tabla de contenido