System Control &
Maintenance
The following commands are used for system control and maintenance. Enter the
command sequences to perform the actions described in the table below.
www.hp.com/racksolutions
All manuals and user guides at all-guides.com
Key Sequence
Action
<CM>Kn<Enter>
Sets the keyboard scan set where n is a scan set number 1-3.
<CM>MR<Enter>
If you hot-plug your mouse cable, you may experience a loss of
mouse signal. Use this command to restore the signal if you are
using a server with a standard PS/2 mouse driver.
<CM>MW<Enter>
If you hot-plug your mouse cable, you may experience a loss of mouse
signal. Use this command to restore the signal if you are using a server
with a Microsoft IntelliMouse or other wheel mouse driver.
<CM>AV<Enter>
Displays the current fi rmware version of your switch.
<CM>SG<Enter>
Enables the scan Go command (By address only)
<CM>SH<Enter>
Enables the scan Halt command
<CM>M+<Enter>
Enables mouse suspension of scanning
<CM>M-<Enter>
Disables mouse suspension of scanning
<CM>H1<Enter>
Changes the hot-key sequence to the default: (NumLock, -)
<CM>H2<Enter>
Changes the hot-key sequence to the 1st alternate: (NumLock, *)
<CM>H3<Enter>
Changes the hot-key sequence to the 2nd alternate: (CTRL, ~)
<CM>OSD0<Enter>
Disables the OSD Sequence
Changes the OSD sequence to the default: (CTRL, CTRL)
<CM>OSD1<Enter>
<CM>OSD2<Enter>
Changes the OSD sequence to the 1st alternate: (Alt, Alt)
Changes the OSD sequence to the 2nd alternate: (Shift, Shift)
<CM>OSD3<Enter>
<CM>ZM<Enter>
Use this command to resynchronize the mouse after a device
or server hot-plug. Repeat, if necessary, until synchronization is
re-established.
Note: Using this command while the mouse is operating cor-
rectly will cause the mouse to lose sync.
Basic Operations