3 GETTING STARTED (continued)
The maximum recording period depends on the number of probes
being used and the specified recording time.
To change the logging interval:
1
If idle, press the 'Func' key to wake the logger.
2
Repeatedly press the 'Func' key until 'INTERVAL' is displayed.
3
Press and hold the 'Set' key for approximately 5 seconds whilst
'Hold to change' is displayed.
4
Set the required logging period using the 'Sel' and 'Set' keys.
5
Press the 'Func' key to exit the menu.
The logging interval can also be set within ElcoMaster
transferred to the logger, see Appendix A 'Using ElcoMaster ' on
page en-13 for further information.
3.7 CONNECTING THE PROBES
The Elcometer 215 has six input sockets
(channels) for K-type temperature probes.
Probes should be connected to each
socket in turn, starting with channel 1,
followed by channel 2, etc.
Each probe plug has a narrow and a wide terminal, ensure that the
plug is orientated correctly before making the connection.
To view details of the probe connected to each channel, press the
'Func' key until 'METER' is displayed and repeatedly press the 'Sel'
key to display each probe in turn. If no probe is connected, 'open' is
displayed.
Note: The Elcometer 215 is not supplied with k-type temperature probes - probes must
be ordered separately, see Section 5.1 'Temperature Probes' on page en-9.
Note: A set of probe identification tags is available to purchase as an optional
accessory to help match each probe with its assigned channel, see Section 5.2
'Probe Identification Tags' on page en-10.