IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING-RISK OF ELECTRIC SHOCK- The pump cannot be using while people are inside the pool.
WARNING-TO REDUCE THE RISK OF INJURY,do not permit children to use this product unless they are closely supervised at all time.
WARNING-RISK OF ELECTRIC SHOCK-Connect only to a grounding type receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact a
qualified electrician if you cannot verify that the receptacle is protected by GFCI.
DO NOT BURY CORD.Locate cord to minimize abuse from lawn mowers,hedge trimmers,and other equipment.
WARNING-To reduce the risk of electric shock,IF FILTER PUMP POWER CORD BECOMES DAMAGED IN ANY WAY, THE PUMP MUST BE
DISCARDED.
WARNING-To reduce the risk of electric shock,do not use extension cord to connect unit to electric supply;provide a properly located outlet.
CAUTION-This pump is for use with storable pools only.Do not use with permanently-installed pools.A storable pool is constructed so that it is capable
of being readily disassembled for storage and reassembled to its original integrity.A permanently-installed pool is constructed in or on the ground or in a
building such that it cannot be readily disassembled for storage.
IMPORTANT- Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRICAL SHOCK- When working with electricity, turn the electrical power off at the circuit breaker and lock breaker door. Failure to do so
will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified
electrician for any questions related to the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord
free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
NOTE:
Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any damaged or
missing parts at the time of purchase. Verify that the equipment components represent the models that you had intended to purchase.
NOTE:
Place pump on a solid and level ground. Pay attention to position of pool and pump so adequate ventilation, drainage, and access for
cleaning is available. Never place pump in an area that may accumulate water, or in an area where foot traffic will flow around the pool.
NOTE:
Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during
periods of cold, heat and exposure to sun. Whenever possible shelter pump from these conditions.
NOTE:
Do not run the pump more than 8 hours per day.
NOTE:
Do not add chemicals in the filter pump.
SAVE THESE INSTRUCTIONS.
PART I
Internal Filter Pump Inspection
1) Remove the Filter Cap by unscrewing the Filter Cap Retainer.
2) Inspect the Filter Cartridge ensuring it is centered in the Filter Pump.
3) After inspection, check that the Filter Cap Seal is in place, replace the Filter Cap and screw the Filter Cap Retainer into position.
PART II
Attach the Hoses to the Filter Pump and the Pool
1) Connect the two Hoses to the pool's Inlet and Outlet Connection Valves by screwing the threaded locking rings into position.
NOTE: Install the Connection Valves following the Connection Valve installation directions.
2) Attach the Hoses to the Filter Pump by pressing the hose fitting on the pump port. Screw the threaded locking rings into position; ensure the
corresponding letters on both the pool and the Filter Pump match (A to A, B to B).
NOTE: After pump is attached to pool, refer to pool manual for filling instructions.
PART III
Preparing the System for Use
1) Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.
Note: If knob becomes dislodged, simply place it back into the hole and turn clockwise to rethread air purge valve.
2) When water comes out of the Air Purge Valve screw it closed and wipe away any water.
3) To start the Filter Pump, insert the plug into a grounding type receptacle protected by a GFCI.
NOTE: To prevent the risk of electrical shock, ensure your hands are completely dry when plugging-in the Filter Pump.
NOTE: To prevent the risk of electrical shock, never run the Filter Pump when people are swimming in the pool.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool's Inlet and Outlet valves are fully covered by water before
operating the Filter Pump.