How to Use the Battery Charger
Use battery float charger jack to keep the starting battery
charged and ready for use. Battery charging should be done
in a dry location, such as inside a garage.
• Plug the charger into the unit's "Battery Float Charger"
jack, which is located on the starter switch (Figure 8).
Plug battery charger into a 120 Volt AC wall receptacle.
Figure 8 — Battery Charger Jack
• Unplug the charger from the unit and the wall outlet when
generator is being started and while it is in operation.
• Keep this charger plugged in when generator is not in
use to prolong battery life.The charger has a built in float
equalizer and will not overcharge the battery, even when
plugged in for an extended period of time.
IMPORTANT: See "Battery Maintenance" on page 14 for
additional information.
10000W Generator
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your generator may
experience icing of the carburetor and/or the crankcase
breather system.
Build a structure that will enclose three sides and the top
of the generator:
• Make sure entire muffler-side of generator is exposed.
Note that your generator may appear different from that
shown in Figure 9.
Figure 9 — Permanent Cold Weather Shelter
• Ensure a minimum of two feet clearance between open
side of box and nearest object.
• Face exposed end away from wind and elements.
• Enclosure should hold enough heat created by the
generator to prevent problems.
CAUTION
enclose generator any more than shown. Remove
generator from shelter when temperature is above
40°F [4°C].
10
Wind
! NEVER run unit indoors. DO NOT