CAME ZBK8 Manual Del Usuario página 8

Tarjeta electronica
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
a
Function selections
1 ON -
Automatic closing - The automatic closing timer is automatically activated at the end of the opening cycle. The preset, adjustable automatic
closing time is automatically interrupted by the activation of any safety system, and is deactivated after a total stop command or in case of power
failure;
2 ON -
Radio function command and/or "open-stop-close-stop" button (with radio-frequency card inserted).
2 OFF - Radio function command and/or "open-close-inversion" button (with radio-frequency card inserted).
3 ON -
Radio function command and/or "only open" button (with radio-frequency card inserted).
4 ON -
"Maintained Action" operations - Operation of the gate by keeping the pushbutton pressed for opening on 2-3, button for closing on 2-4 (excluding
the radio transmitter operations).
5 ON -
"Pre-fl ashing during opening and closing" - After an opening or closing command, the fl ashing lamp connected to W-E1 fl ashes for 5 seconds
before beginning the manoeuvre.
6 ON -
Obstacle detection - With the motor not running (gate closed, open or after a total stop command), this hinders any movement if the safety devices
(e.g. photoelectric cells) detect an obstacle.
7 OFF
Re-opening during closure - If the photoelectric cells identify an obstacle while the bar is closing, they will reverse the direction of movement
until the gate is completely open; insert safety device on the clamp (2-C1); if not used, select the dip in ON.
8 OFF - Partial stop - The gate stops if in motion with resulting order of automatic closing, insert safety device on the clamp (2-C3); if not used, set the
dip to ON.
9 OFF - Operation of the safety test of the photoelectric cells - The central unit can check the effi ciency of the safety devices (photoelectric cells) after
every opening or closing command.
10 OFF- Total stop - This function stops the gate, with the resulting exclusion of an automatic closing cycle; to resume movement, the pushbuttons or
transmitters must be used. Insert the safety device on (1-2); if not used, set the dip to ON.
b
Adjustments
- Trimmer A.C. = Automatic closing time. Adjusts the wait time of the gate in the open position, also known as "pause
time"; at the end of this time, a closing movement is automatically activated. The "pause time" can be adjusted from
1 second to 140 seconds.
- Trimmer PAR.OP. = Partial opening. Adjusts the opening time of the gate. By pressing the partial opening button on
2-3P, the gate will open for a set time between 1 and 15 seconds.
8
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.

Publicidad

Tabla de contenido
loading

Tabla de contenido