Important! The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
31450000: The flow is changed from bath to shower
function by pulling the knop at the upper side of the
spout. After shutting off the water flow, the mixer
returns automatically to the bath function.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work - Flow limiter in handshower isn't
6
English
Connections G 1⁄2":
Rate of flow 3 bares:
anti-pollution function
To adjust the hot water limiter on single lever mixers,
please see page 22.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 1.5 bars.
Spare parts (see page 3)
1
1.1 screw cover
2
3
4
5
max. 10 bars
6
7
1 - 5 bars
16 bars
8
max. 80° C
9
65° C
10
150 ± 16 mm
11
Cause
- Shower filter seal dirty
- Non return valve hasn't moved
back
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
removed
- Filter are dirty
- Non return valve didn't move
back
handle
flange
nut
cartridge cpl.
escutcheon
S - unions
aerator cpl.
selector
diverter knob
non return valve
noise reduction
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves
cold right
hot left
approx. 22 l/min
31092000
96338000
94192000
94194000
92730000
94135000
94140000
13956000
94077000
94078000
94074000
96429000

Publicidad