2 - Inspection of the direction of travel
Note: invert V and W if the motor faces left (as seen from inside the device).
N.B.: in this case you need to press and hold the PROG button to operate. Operation is step by step so
each press of the button stops-closes-stops-opens, etc.
The LEDs confirm whether configuration is correct, as described below.
a) Turn OFF DIP switches 1-2-3-4-5-6-7 and 8.
b) Press the OPEN button (the shutter opens)
c) When fully open, the limit switch is activated by the cam and the motor stopped.
d) Release the OPEN button.
e) Press the CLOSE button (the shutter starts to close)
f) When fully closed, the limit switch is activated and the motor stopped.
g) Release the CLOSE button.
WARNING: Make sure the electric end travels act BEFORE the gate reaches the mechanical pads of
the end travel. This ensures safe operation.
h) Disconnect the power from the panel.
i) Set the DIP switches 1-2 to ON and 3-4 to OFF.
l) Reconnect the power to the panel.
3 - Adjustment of the automatic closing time.
The pause time before the automatic closing can be set between 1 to 60 seconds.
You can enable / disable automatic closing and save its value by doing the following:
1) Stop the operator.
2) Press the RADIO LEARN button on the control panel for more than 5 seconds => The panel emits a double beep repeatedly.
3) Release the RADIO LEARN button
4) Set the pause time before the automatic closing time 1s ÷ 60s by turning the RUN TIMER trimmer.
Turn clockwise the "RUN TIMER" trimmer to
increase the automatic closing time.
-
+
RUN TIMER
5) Press and release the RADIO LEARN button to confirm the selected time => The box will confirm the memorization of the selected time with an extended beep.
4 - Adjustment of the run time (DIP 3 - OFF)
Allows the setting of the automation run time to values between 1.5 and 90 seconds.
The run time is disabled if the deadman mode is set.
Rotate the "RUN TIMER" trimmer clockwise to
increase the run time.
-
+
RUN TIMER
5 - Programming the remote control
1 - Press the RADIO LEARN button => the buzzer emits long beeps for 20 seconds.
2 - While the buzzer emits long beeps, press button "A" on the remote control.
3 - The two buttons "A" and "B" are stored.
6 - Personalizing configuration
The micro-switches allow you to change the configuration
Change the position of the DIP switches only while the panel is unpowered!
Always disconnect the power when changing the settings.
dip
Function
1
Opening
2
Closing
3
Run timer
4
Impulse
IMPORTANT: The system must comply with all the standards and Directives currently in force.
Dip OFF
Deadman
Impulse open
Deadman
Impulse close
Programmable
Infinite
Open - Close
GO function
DEADMAN OPEN
DEADMAN CLOSE
ADJ RUN TIMER
OPEN FUNCTION
-
+
RADIO LEARN
RUN TIMER
LED
POWER ON
PHOTO
STOP
1
2
STOP COM OPEN CLOSEPHOTO
Turn counter clockwise the "RUN TIMER" trimmer to
decrease the automatic closing time.
Rotate the "RUN TIMER" trimmer anticlockwise to
decrease the run time.
Dip ON
GND ANT
IMPULSE OPEN
IMPULSE CLOSE
INFINITE RUN TIMER
GO FUNCTION
17 18
P1
TRASF
T 6,3A
8
9
10
3 4
5
6
7
L
PE
230Vac
-
+
24Vdc
o/ou/or
120Vac
RAD1
BZ
11
12 13 14 15 16
U W V
N
N
L
L
N
L
MOTOR
LIGHT
-
+
RUN TIMER
-
+
RUN TIMER