Placing Tool In Service - Ingersoll Rand 172–EU Serie Instrucciones

Ocultar thumbs Ver también para 172–EU Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Accessory Installation
Always turn off the air supply and disconnect the air
supply hose before installing, removing or adjusting any
accessory on this tool or before performing any
maintenance on this tool.
LUBRICATION
Ingersoll–Rand No. 10
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For International – No. C08–C2–FKG0
Before attaching the air hose, place about 3 cc of
Ingersoll–Rand No. 10 Oil into the air inlet. This should be
done each day, even when an air line lubricator is used.
During the working day, check the tool to ensure that the
retainer components are lubricated.
After each two or three hours of operation, if an air line
lubricator is not used, disconnect the air hose and pour about
3 cc of Ingersoll–Rand No. 10 Oil into the air inlet of the tool.
If the action of the Scaler becomes sluggish, pour about
3 cc of a suitable cleaning solution into the air inlet and run
the tool for not more than thirty seconds. Immediately after
flushing the tool, pour about 3 cc of Ingersoll–Rand No. 10
Oil into the air inlet and run the tool for about thirty seconds
to lubricate internal parts.
Model
172L–EU
182L–EU
182G–EU
outside trigger
172LNA1–EU
lever throttle/needle
182LNA1–EU
lever throttle/needle
H
Tested in accordance with PNEUROP PN8NTC1.2 under load
Tested in accordance with ISO8662–2
ISO3744
ADJUSTMENTS

PLACING TOOL IN SERVICE

SPECIFICATIONS
Handle
Blows
per min.
lever throttle
5,500
lever throttle
4,000
grip with
4,000
5,500
4,000
To install or remove a Chisel or other accessory, depress the
Retainer Sleeve Lock Plunger and rotate the Retainer Sleeve
to the right as far as the slot in the Sleeve permits. Install or
remove the accessory and rotate the sleeve to the left until the
Lock Plunger snaps outward and locks the Sleeve against
rotation in either direction.
Before storing a Scaler or if the Scaler is to be idle for a
period exceeding twenty–four hours, pour about 3 cc of
Ingersoll–Rand No. 10 Oil into the air inlet and operate the
tool for 5 seconds to coat the internal parts with oil.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
FILTER
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
HSound Level
Piston Stroke
in (mm)
Pressure
9/16 (14)
110.5
1–1/16 (27)
110.2
1–1/16 (27)
110.2
9/16 (14)
110.5
1–1/16 (27)
110.2
3
COMPRESSOR
(Dwg. TPD905–1)
♦Vibrations
dB (A)
Level
•Power
m/s
123.5
10.5
123.2
12.7
123.2
12.7
123.5
10.5
123.2
12.7
2