TECHNICAL DATA

Dial Position
Current AC
Current DC
Voltage AC
Voltage DC
Resistance
Continuity
Capacitance
Hertz
*These instruments are True-RMS sensing. All voltage and current readings are True-RMS values.
Accuracy is specifi ed for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0 % to 85
%.
Maximum voltage between any terminal and earth ground
Jaw Opening (maximum conductor size)
Temperature Operating
Temperature Storage
Temperature Coeffi cient
Operating Altitude
Battery
Weight with battery
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS Measuring Instrument
Never make measurement on a circuit in which voltage over
600 V exists. Use only leads rated 600 V or better.
Clamp tips are designed not to short the circuit under test. If
equipment under test has exposed conductive parts, however,
extra precaution should be taken to minimize the possibility of
shorting.
Disconnect the test leads from the instrument for current
measurement.
Keep fi ngers away from jaws during measurements.
To reduce the risk of electric shock for Resistance, Continuity,
and Capacitance measurements, never use the meter on an
energized circuit. Make sure a capacitor is fully discharged
before touching or attempting to make a measurement.
Do not attempt to make measurement in the presence of
fl ammablegasses. Otherwise, the use of the instrument may
cause sparking, which can lead to an explosion.
Never attempt to use the instrument if its surface or your hand
is wet.
Do not exceed the maximum allowable input of any measuring
range.
Only test on unenergized circuits unless absolutely necessary.
Check tool functionality on a known circuit fi rst.Never
assume tool is working. Assume circuits are live until they
can be proven de-energized.
28
ENGLISH
414 014 - ClampMeter 2237-40.indd 28
414 014 - ClampMeter 2237-40.indd 28
All manuals and user guides at all-guides.com
Range
0.5 - 600 A
Peak 1500 A
CF=2.5@600A
CF=3.0@500A
0-600.0 A
0.05 - 60/600 V
60/600 V
600 Ω/6 kΩ
0-600.0Ω
0.01nF - 4000μF
Auto-ranging
ACA: 40-400 Hz
ACV: 1Hz-10 kHz
Resolution
0.1 A
0.1 A
0.01 V / 0.1 V
0.01 V / 0.1 V
0.1 Ω / 0.001 kΩ
0,1 Ω
0.01nF/0.1nF/
0.001μF/0.01μF
0.1μF/1μF
0.001/0.01/0.1/
0.001k/0.01k
0,1 x specifi ed accuracy /°C (<18°C or >28°C)
Do not ground yourself while measuring. Avoid body contact
with earthed or grounded sur-faces such as pipes, radiators,
ranges and refrigerators.
Never remove the case or battery cover during a measurement.
This instrument is to be used only in its intended applications or
conditions. Otherwise, the instrument's safety functions may
not work, resulting in serious personal injury and instrument
damage.
To reduce the risk of injury from shock and arc blasts, always
wear personal protective equipment where live conductors are
exposed.
Never attempt to make measurement if any abnormal
conditions, such as broken case and exposed metal parts are
found on the instrument.
Do not rotate the Rotary Dial while the test leads are being
connected.
Do not install substitute parts or make any modifi cation to the
instrument. For repair or re-calibration, return the tool to a
factory Service/Sales Support Branch or authorized service
station.
Only use Milwaukee test leads with the Milwaukee Clamp
Meters.Inspect test leads before each use. Use clamp meter to
run a continuity test.
Non-Contact Voltage Detection (NCVD):
The LED may not be displayed due to installation condition of
electrical circuit or equipment. Never touch the circuit under
test to avoid possible danger even if the LED for NCVD is not
displayed. Check the functionality of LED on a well-known
power supply prior to measurement. When the LED doesn't
light up, do not make measurement. NCVD indication is
affected by external voltage, and how the meter is held or
placed.
Accuracy
±2.0%rdg ±5dgts, 50Hz/60Hz
±3.5%rdg ±5dgts, 40Hz - 500Hz
±5.5%rdg ±5dgts, 500Hz - 1kHz
Add 2% at CF>2*
≤ 5A, add 3dgt
±1.5%rdg ±5dgt
±1.5%rdg ±4dgts, 50Hz/60Hz
±3.5rdg ±5dgts, 40Hz - 400Hz
±1%rdg±3dgt
±1%rdg±5dgt
Buzzer sounds at 30Ω or less
0.01nF-39.99nF ±2.5%±2nF
40.00nF-1000μF ±2.5%±20dgt
1000μF> ±5%±20dgt
ACA: 40-400Hz ±0.5%rdg±5dgt
ACV: 1Hz-10kHz ±0.5%rdg±5dgt
min 40 Vrms for VAC
min 50 Arms for ACA
CAT III: 600 V
33 mm
-10°C - 50°C
-40°C - 60°C
2000 m
2AA
?? g
10.06.2010 09:27:50
10.06.2010 09:27:50