Specified Conditions Of Use; Sleep Function - Milwaukee 2237-40 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Measurement categories and their signifi cance according
to IEC 61010-1:
CAT III: Measurements in the building installation: stationary
loads, distribution board, device fi rmly on the distribution board.
SAFETY INSTRUCTIONS Battery
This tool is designed to be powered by 2 AA batteries
properly inserted into the instrument. Do not attempt to use
with any other voltage or power supply.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands (or
types within brands) of batteries.
Do not mix rechargeable and non-rechargeable batteries.
Install batteries according to polarity (+ / –) diagrams.
Properly dispose of used batteries immediately.
Battery acid may leak from damaged batteries under extreme
load or extreme temperatures. In case of contact with battery
acid wash it off immediately with soap and water. In case of eye
contact rinse thoroughly for at least 10 minutes and
immediately seek medical attention.
This appliance is not intended for use by persons (including
children) with limited physical, sensory or mental capabilities or
insuffi cient experience and/or knowledge unless they are
supervised by a person who is responsible for their safety or
have been instructed by them in the safe use of the tool.
Children should be supervised in order to ensure that they do
not play with the tool.

SPECIFIED CONDITIONS OF USE

The Measuring Instrument can be used for following
measurements: Current AC, Current DC, Voltage AC,
Voltage DC, Resistance, Continuity, Capacitance,
Frequency. This instrument may only use for measuring the
previously indicated measurements.

SLEEP FUNCTION

This instrument is automatically powered off in about 20 min after
the last Rotary Dial or button operation. To reset, rotate the Rotary
Dial or press a button.
WORKING TIPS
Set the Rotary Dial to an appropriate position before starting
measurement.
Firmly insert the test leads.
Disconnect the test leads from the instrument for current
measurement.
Do not expose the instrument to the direct sun, high
temperature and humidity or dew fall.
Altitude 2000 m or less. Appropriate operating temperature is
within -10ºC and 50ºC.
This instrument isn't dust & water proofed. Keep away from
dust and water.
Be sure to power off the instrument after use. When the
instrument will not be in use for a long period, place it in
storage after removing the battery pack.
Use a damp cloth or neutral detergent for cleaning the
instrument. Do not use abrasives or solvents.
414 014 - ClampMeter 2237-40.indd 29
414 014 - ClampMeter 2237-40.indd 29
All manuals and user guides at all-guides.com
MAINTENANCE
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or
directly at: Milwaukee Electric Tool, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national
law, electric tools that have reached the end
of their life must be collected separately and
returned to an environmentally compatible
recycling facility.
WARNING
To avoid electrical shock remove test leads
before opening case or removing battery.
Ground
Double isolated
Never make measurement on a circuit in
>600 V
600
600 00
which voltage over 1000V exists.
Keep fi ngers away from test tips during
measurements.
ENGLISH
29
10.06.2010 09:27:50
10.06.2010 09:27:50

Publicidad

Tabla de contenido
loading