Troubleshooting; Environmental Protection - BGS technic 8343 Manual De Instrucciones

Bomba de palanca para bidones
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

PROBLEM
Leakage of
media from
the pump
Pump does not
dispense fluid or
does not prime
Handle difficult
or impossible
to move

ENVIRONMENTAL PROTECTION

Dispose of this product at the end of its working life environmentally. Recycle
unwanted materials instead of disposing of them as waste. All tools, accessories and
packaging should be sorted, taken to a recycling centre and disposed of in a manner
which is compatible with the environment. Contact your local solid waste authority for
recycling information
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
POSSIBLE CAUSE
Damaged seal (O-ring)
due to use with media
not suitable for use with pump
Pump not able to
create adequate suction
Pump is drawing in air,
instead of fluid
Suction tube inlet is clogged
Compression nut is too tight
Pump has not been used
for a long time
Damaged or worn pump parts
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
SOLUTION
Replace seal (O-ring)
with genuine replacement seal
(O-ring) from manufacturer
and use only recommended
media with the pump.
Prime the pump. Reverse the
discharge spout on the
pump & pour the fluid being pumped, into the
outlet & operate the pump handle till fluid
starts dispensing.
Tighten all connections of
suction tube & of the suction tube
with pump inlet. Inspect pump
over(s) and seals for leaks.
Remove suction tube &
clean the tube inlet
Loosen the compression nut
Remove pump cover and inspect
for deposits on components and
corroded parts. Clean or replace parts. Flush
pump with the media
being used if pump is not in
use over long periods of time.
Remove pump cover &
inspect internal parts.
Replace worn or damaged parts
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed