Specifications
Model No.
Type
Nominal Compressor
Capacity (KW)
Electrical Rating
Full Load Amps
(Compressor / Motor)
Locked Rotor Amps
(Comp / Motor)
Refrigerant R407C
Grams/Oz.
Circuit Protection
input Power (KW)
Minimum Wire Size
** generator Size
** The manufacturer gives GENERAL guidelines for
generator requirements. These guidelines come from
experiences people have had in actual applications.
When sizing the generator, the total power usage of your
caravan must be considered. Keep in mind generators lose
power at high altitudes and from lack of maintenance.

INSTALLATION INSTRUCTIONS

A. Precautions
Improper installation may damage equipment,
could endanger life, cause serious injury and/
or property damage.
. Read Installation and Operating Instructions care-
fully before attempting to start your air conditioner
installation.
2. The manufacturer will not be liable for any dam-
ages or injury incurred due to failure in following
these instructions.
3. The equipment shall be installed in accordance
with national wiring regulation per iEC 335-2-40, Ci,
7.12.1. Installation must comply with all applicable
codes and/or regulations.
4. DO NOT add any devices or accessories to this
air conditioner except those specifically authorized
by the manufacturer.
5. This equipment must be serviced by qualified
personnel and some local codes and regulations
require these people to be licensed.
B3200
Electric
Heater
3253.333
3.2
.6
220-240 VAC 50Hz.,  Ph
5.2 / .
--- / .
26/ 3.8
---/ 3.8
496/5.5
---
0 Amp Time Delay Fuse,
or Circuit Breaker
.35
.5
Up to 8 meters
use  mm
, Copper
2
 Unit - 3.5KW
2 Units - 5.0KW
B. Choosing Proper Location for The Air
Conditioner
This air conditioner is specifically designed for installation
on the roof of a caravan. When determining your cooling
requirements, the following should be considered:
Size of caravan;
Window area (increases heat gain);
Amount of insulation in walls and roof;
Geographical location where the caravan will be
used;
Personal comfort level required.
. Normal Location-The air conditioner is designed
to fit over an existing roof vent opening.
fig. 1
2. Other locations-When no roof vent is available or
another location is desired, the following is recom-
mended:
a. For one unit installation: The air conditioner
should be mounted slightly forward of cen-
ter (front to back) and centered from side to
side.
b. For two unit installations: Install one air con-
ditioner /3 and one air conditioner 2/3's from
front of caravan and centered from side to
side.
fig. 2
1/2L
3
L
L
2/3L
1/3L