Inst allation
1. (Exhaustair mode) prepare suitable
exhaust-air conduction in the ceiling.
2. Determine the control side of the hood;
the control panel is on this side.
3. T o obtain Optimum extraction cap
centre the extractor hood over the hotplate
(use a plumb) and mark the centre point of
the tower on the ceiling.
4. Mark the positions for the fixing holes with
the aid of the template.
5. Determine dimension (X - Y); X = distance
between the cooking surface and the
ceiling, Y = distance between the cooking
surface and hood.
6. Drill four holes (10 mm) and insert wall
plugs flush with the wall.
All manuals and user guides at all-guides.com
acity ,
7. Screw wood-to-metal dowel screws into
the wall plugs, leaving them projecting
by20mm.
8. Guide the exhaust-air hose (exhaustair
mode) and connection cable down from
the ceiling. Exhaustair hose should be
approx. 10 cm longer than the upper
tower .
9. Mark the positions for four holes on the
upper tower with the aid of dimension (X
- Y).
Use stickon tape measure. Drill holes (6 mm).