The total volume meter is managed at this level; it counts up from 0 irrespective
of the cartridge change.
Memory Call-Up
In the Memory Call-Up mode, the data of the last 4 filter cartridges used can be called up.
Briefly press button once (< 1 second) until the following message appears:
-1, -2, -3, -4 level – data of the cartridges used before the current one.
Carbonate hardness By-pass
Total meter reading when
changing the filter cartridge
At the top left, the indicator for the filter cartridge (-1 for previous filter cartridge) is displayed
alternately with the water hardness set and the hardness unit. At the top right, the filter system
size is displayed alternately with the bypass setting (display 1 s indicator, 1 s water hardness),
at the bottom left, the meter reading when changing the cartridge (-1) and at the bottom right,
the installation date of the cartridge.
Meaning: the filter cartridge most recently used was a PURITY 1200 cartridge, the filter cartridge
was inserted on 06/25/09 and operated up to a meter reading of 6619 US gallons. The water
hardness set was 14°gpg and the bypass measured was 30 %.
The same applies to the cartridge (-2), preceding filter cartridge and the other preceding filter
cartridges -3,-4.
EN
Error Messages
Error level E1 indicates whether an error has occurred in blend detection.
E1 is activated as soon as the current bypass is not correctly identified.
The word Start is then displayed together with the date of occurrence.
As soon as the current bypass setting is identified correctly again, the error has ended and the Stop
date is added. At error level 01 the Stop and Start display alternates every second.
Error level E2 indicates whether and from when until when an error has occurred at the outlet water
meter. Display is similar to level E1.
16
Cartridge indicator
alternating
Date of inserting the cartridge
alternating
Type