10.4 Leak after Filter Replacement
Cause:
Troubleshooting:
10.5 No Display Function
Cause:
Troubleshooting:
10.6 Data on Display Flashing
Cause:
Troubleshooting:
10.7 Bypass setting in the display does not agree with the setting
of the bypass screw (cf. 10.8/10.9)
Cause:
Troubleshooting:
10.8 Bypass setting in the display does not agree with the setting
of the bypass screw (cf. 10.7/10.8)
Cause:
Troubleshooting:
11 Battery
EN
The installed battery is designed for a service life of approx. 10 years.
The battery and display unit must not be burnt and must not be disposed of in domestic waste;
please hand in the battery and the appliance to the collecting points designed for this purpose in
line with the local regulations.
To remove the battery, please proceed as follows:
Remove the screw on the back of the display unit and open and remove the back of the housing.
Disconnect the soldered contacts on the battery with side cutters and remove the battery from
the bracket.
Replace back of the housing on the display unit and tighten screw.
Dispose of the battery and display unit following
the local environmental guidelines for battery disposal

12 Technical Data

Operating pressure
Operating/water temperature
Ambient
temperature
during
Flow rate with 1 bar (14.5 psi)
pressure loss
Nominal flow according to Norm
18
O-ring at the fi lter cartridge is not seated correctly.
Check correct seat of the O-ring (Chapter 6.2).
Caution: Prior to dismantling read the data (Chapter 12) and the Operating
!
and Safety Information (Chapter 3).
Battery drained.
Replace display unit (Order number see Chapter 13).
Note: When replacing the display unit, follow the enclosed manual.
Monthly limit expired or the remaining capacity of the filter cartridge
is exhausted (Chapter 5.2).
Replace filter cartridge (Chapter 6).
Filter was not commissioned correctly.
Flush filter again (Chapter 5.4). Check data in the display after flushing
(Chapter 5.5).
Valve strip of the by-pass setting not set correctly.
Flush filter system again and readjust bypass screw (Chapter 5.3)
PURITY 450 Quell ST
MDU*
operation
storage/transport
300 l/h (79.2
US gallons/h)
60 l/h (15.85
US gallons/h)
.
Filter system VIVREAU PURITY with filter cartridge
PURITY 600 Quell ST
distributor
MDU*
head
2 bar – max. 6,9 bar (29 psi – max. 100 psi)
4°C – 30°C (39°F – 86°F)
10°C – 40°C (50°F – 104°F)
–20°C – 50°C (–4°F – 122°F)
350 l/h (92.4
300 l/h (79.2
US gallons/h)
US gallons/h)
60 l/h (15.85
120 l/h (31.7
US gallons/h)
US gallons/h
PURITY 1200 Quell ST
distributor
MDU*
head
350 l/h (92.4
300 l/h (79.2
US gallons/h)
US gallons/h)
120 l/h (31.7
120 l/h (31.7
US gallons/h
US gallons/h
distributor
head
350 l/h (92.4
US gallons/h)
120 l/h (31.7
US gallons/h)