Electrical Connection - Graf 106589 Instrucciones Para La Instalación Y El Montaje

Armario de distribución externo para el armario interior pp
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Electrical connection

The electrical connection of the switch cabinet must only be carried out by a
qualified electrician!
An underground cable must be laid to the cabinet for the power supply. This cable
must be protected by a 16 amp fuse via the building installation and must be
able to be disconnected from the mains.
Fuse
connections
The electrical connection is made via a double socket. The double socket is included with the exterior
switch cabinet and is installed in the PP switch cabinet:
The top-hat rail of the double socket must be
screwed to two fastening points on the PP cabinet.
The underground cable is electrically connected to
the left-hand double socket.
Qualified electrician required!
For commissioning, the protective earth plug of the control cabinet must be plugged into one of the two
sockets.
5. Electrical connection
The double socket must be moved sideways on
the top-hat rail for access to the fastening points.
/