• Do not use charcoal.
• Do not use an adjustable low pressure regulator.
GB
Follow these instructions carefully to avoid seriously damaging your barbecue.
a) FOR YO R SAFETY
- Do not store or use petrol and other flammable liquids or
vapours in the vicinity of this barbecue. If you smell gas:
1) Close the valve of the cylinder
2) Extinguish all naked flames
3) Open the lid
4) If the smell continues ,see "
immediately seek advice from your local retailer.
b) LOCATION
- This barbecue must only be used outdoors.
Caution:
-
accessible parts may get very hot. Keep
young children away.
- There should be no combustible materials within a
radius of approximately 60 cm around the barbecue
- Do not move the barbecue when alight.
- The appliance should be operated on a level surface.
- Estimated air offtake 2 m
c) GAS CYLINDER
This barbecue has been adjusted to be operate off 4,5 to
15 kg butane/propane cylinders with an appropriate low
pressure regulator:
- France, Belgium, Luxembourg,
Ireland, Portugal, Spain, Italy, Croatia, Greece :
28 mbar / propane 37 mbar.
Netherlands, Czech Republic, Slovakia, Hungary,
-
Slovenia, Norway, Sweden, Denmark, Finland,
Switzerland, Bulgaria,Turkey, Romania:
/ propane 30 mbar.
Poland:
-
propane 36 mbar.
- Germany, Austria:
Always connect or replace the cylinder in a well-ventilated
area, never in the presence of a flame, spark or heat source.
The gas cylinder equipped with the regulator should
not be put under the barbecue if its total height
exceeds 46.5 cm.
When the gas cylinder is put under the barbecue, it must
be attached to the frame of the barbecue using the
supplied strap.
d) Hose
France (depending on model)
The equipment may be used with two types of flexible
hose:
a)
flexible hose designed to be joined onto ringed
tailpieces on both the barbecue and regulator sides,
held firm with collars (in accordance with standard XP
D 36-110). Recommended length 1.25 m.
G 1/2
barbecue
b)
flexible hose (according to standard XP D 36-112) fitted
with a G 1/2 threaded nut for fixing to the barbecue and
a M 20x1.5 threaded nut for fixing to the regulator,
recommended length 1.25 m.
G 1/2
barbecue
All manuals and user guides at all-guides.com
Operation and maintenance
f
Checking for gas leaks" or
3
/kW/h.
nited Kingdom,
butane 30 mbar
butane / propane 36 mbar.
black
The barbecue has a G 1/2 threaded gas inlet
connector supplied with pre-fitted NF ringed tailpiece
and seal.
1) To use the equipment with the flexible hose XP D
36-110: (solution d) a))
- slide the flexible hose onto the ringed tailpiece on both
the barbecue and regulator as far as it will go.
- slide the collars behind the two first bosses on the
tailpieces and tighten them until the tightening head
breaks.
- check for leaks following the instructions in paragraph f).
2) To use the equipment with the flexible hose XP D
36-112, G 1/2 and M 20x1.5 nuts: (solution d) b))
- loosen and remove the NF ringed tailpiece to release
the G 1/2 inlet connector.
- remove the seal
- tighten the G 1/2 threaded nut on the hose onto the
barbecue inlet connector and the M20x1.5 threaded nut
onto the regulator output connector following the
instructions supplied with the flexible hose.
butane
- use a spanner to hold the barbecue inlet connector firm
and tighten or loosen the threaded nut with another
spanner.
spanner to hold the regulator outlet connector firm.
- check for leaks following the instructions in paragraph f).
Check that the flexible hose stretches out normally
without twisting or pulling and does not come into contact
with the hot sides of the barbecue. It should be replaced
when the expiry date on the hose is passed or whenever
it is damaged or develops surface cracks.
M 20x1,5
Belgium, Luxembourg,
Portugal, Spain, Italy, Croatia, Greece, Netherlands,
Regulator
Czech Republic, Slovakia, Hungary, Slovenia, Norway,
Sweden, Denmark, Finland, Bulgaria, Turkey, Romania,
Poland:
The barbecue is equipped with a circular connector. It
should be used with flexible hose that is suitable for use with
M 20x1,5
butane and propane gas. Hose length should not exceed
1.20 metre. It should be replaced if it is damaged or
develops surface cracks or when so required by national
legislation. Do not pull or pierce the hose.
Regulator
6
- use
nited Kingdom, Ireland,
a