Note: When performing any operation on the DC65, take care that it is not fitted on
the power tool, so as to prevent any risk of an accident.
4.1 Installing a tool holder (facing and chamfering):
Firstly, remove the front part of the DC65 by unscrewing the feed crank.
In the case of a facing tool holder, install the tool holder on the plate, and then adjust
its position according to the diameter to be machined (centre the plate on the tube
thickness).
In the case of a chamfering tool holder, position the tool holder on the plate, install the
front part and then install the tube to be machined. Position the plate tangentially on the
tube (to obtain the chamfer starting point), then move the chamfering tool holder towards
the centre, as a function of the depth of chamfer required: 1 mm displacement = 1 mm of
chamfer depth.
Caution, for chamfering only, the tool at 45° allows a maximum chamfer depth of
5 mm, while the tool at 30° allows a maximum depth of 7 mm.
In order to blunt the outer edge of the tube, the chamfering tool may be used at the
same time as the facing tool (mounted symmetrically). Conversely, to perform the
two operations simultaneously, with full adjustment travel, the tube diameter must
not exceed 52 mm.
Finally, lock the tool holder in position by tightening the locking screw (ref. 1), using the
Torx T15 screwdriver supplied (tighten to torque 2.55 Nm).