NOTE:
It is possible to mount two tool holders symmetrically in relation to the axis of rotation of
the machine. Check that the tool holders are mounted with locking screws facing
outwards.
This mounting balances machining loads which will result in a longer machine life
cycle and also less frequent changing of the HSS plate (longer servicing intervals).
It is also possible to install the facing tool holder and a chamfering tool holder, which
enables the two operations to be performed simultaneously.
Caution, the setting up of the chamfering tool holder is very important and must be
very precise (see 4.1). The chamfering cut depth remains 3 mm with the tool holder
at 45°, and 6 mm with the tool holder at 30°.

4.2 Installing the clamping jaws

 Check the outside diameter of the tube to be machined.
 Choose the jaws depending on the diameter of the tube to be
machined.
 Position the bottom jaw and then tighten screw IDIN912-M3x12
(tightening torque = 1.23 Nm, 2.5 mm Allen key supplied).
Screw reference 1
Chamfering cut depth
(tool travel)