Thank you for purchasing this Price Pfister product. All Price Pfister
products are carefully engineered, and factory tested to provide long
trouble-free use under normal conditions. This product is easy to
install using basic tools and our easy to follow illustrated instructions.
If you have any questions regarding this product, call 1-800-Pfaucet
(1-800-732-8238).
PRELIMINARY STEPS
1 BEFORE PROCEEDING
WARNING: Read all the instructions completely before proceeding. Price Pfister
recommends calling a professional if you are uncertain about installing this product!
This product should be installed in accordance with all local and state plumbing and
building codes. For optimum performance of your new Price Pfister faucet, a minimum
water pressure of 25 PSI (172 kPa) is recommended.
Your installation will require supply tubes. To preserve the high flow characteristics of
1
these valves, it is necessary to use
/
2
Quick Connect Hose Kit 15-136R. Consult the store where you purchased your faucet
for the recommended connections that you may require for your area.
3
If Deck Thickness Exceeds 1
/
" (35mm), Price Pfister Stem Extension Kit 974-
8
375 must be used.
2 SHUT OFF WATER SUPPLY
Locate water supply inlets and shut off the water supply valves. These are usually
found near the water meter. If you are replacing an existing faucet, remove the faucet
from the tub and clean the tub surface thoroughly.
3
3 TOOLS RECOMMENDED:
● PTFE Plumber's Tape or Thread Sealant
● Slotted screwdriver
● Phillips Screwdriver
● Pipe Wrench
● Flashlight
Your installation may require new supply lines and/or shut-off valves. For soldered copper
and non-standard installations, some additional tools may be required.
4
a
b
A
B
4
1
/
"
2
3
1
/
"
a
2
f
e
2
1
/
"
2
5
" I.D. (
/
" O.D.) Copper tubing or Price Pfister
8
● Adjustable wrench
● Clot
28"
4
1
/
"
2
a
c
b
a
C
7"
ENGLISH
4 RECOMMENDED COMPONENT LOCATIONS
Note: Recommended all holes 1
movement, the area under the deck, in the hose path, must be free of obstructions.
A. In-line Installation:
1
4
" (114 mm) Minimum spacing between End Body Holes (a) and Spout Hole (b).
/
2
Maximum distance between Hand Held Shower Hole (c) and Spout Hole (b) is 28"
(712 mm).
B. Offset Installation:
Hole offset should be a minimum of 0" to 3
minimum of 4
Spout and Handle Holes (f) must be a minimum of 2
C. Custom Installation:
7" (178 mm) Minimum spacing between hub holes for side-by-side handles
installation.
5
1
3
/
"
8
(35 mm)
c
5 END BODY INSTALLATION
Remove Upper Locknut (5A) and Washer (5B) from Valve Body (5C). From underneath
deck, position Valve Body (5C) through deck hole and adjust Lower Locknut (5D) and
Washer (5E) so that top of supply valve stem is 1
Assemble Upper Washer (5B) and Locknut (5A). Wrench tighten Locknuts (5A/5D). If
Deck Thickness Exceeds 1
For Thick Wall Installation Go Step 10
2
1
" (32 mm) diameter. To ensure adequate hose
/
4
1
" (0 - 89 mm). Hole offset should be a
/
2
1
" (114 mm) (d). Hole forward offset from Tub Wall (e) to center line of
/
2
FAUCET INSTALLATION
5A
5B
5C
5C
1
5
/
"
8
(41 mm)
5A
5D
5C
5
" (41 mm) above mounting surface.
/
8
3
" (35 mm), proceed to Thick Wall Installation (step 10).
/
8
1
/
" (64 mm).
2
5A
5B
5E
5D