Maintenance & Care - Black and Decker Price Pfister 0X6 Serie Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12
12 PRESSURE TEST
For pressure testing prior to trim installation, seal the Spray Hose (12A) with Plug (12B)
and Outlet Tube (12C) with Plug (12D). Run water and perform pressure test. Look
for leaks.
WARNING: Pressure testing is not to exceed 250 PSI (1724 kPa). Make sure
pressure is balanced between hot and cold inlets.
WARNING: Differential pressure of hot and cold inlets must not exceed 100
PSI (689 kPa).
CAUTION: Slowly remove pipe plugs (12B/10D) to relieve pressure.
Proceed with trim installation.
MAINTENANCE & CARE
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you purchased
your faucet.
2.
When replacement parts are not available, please write or call Price Pfister
Consumer Service.
3.
Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all handles and decorative finishes, use only a soft damp cloth
to clean and shine. Use of polish, detergents, abrasive cleaners,
organic solvents or acid may cause damage. Use of other than
a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain porcelain or other similar substance
are not acceptable for public areas or Commercial use. Installation
of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com
• Installation Support
• Care and Warranty Information
12B
12A
12D
12C
ENGLISH
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Price pfister 0x6-440rPrice pfister 0x6 seie

Tabla de contenido