TREATMENT
6.
Press the power level setting and on/off button (5A): the green power level
1 LED (5B) lights up and the ventilation system is activated (you will hear
a sound similar to that of a hair dryer).
7.
About 1 second after having pressed the power level setting and on/off
button (5A), the skin colour/device-is-ready LED (5C) lights up: the device
is automatically set to the lowest power level.
8.
Set the lowest power level when applying the first treatment. Follow the
instructions in the "Information before use" chapter if you wish to use a
different power level for follow-up sessions.
9.
Apply the treatment surface (1A) firmly on the skin. Only when the treatment
surface (1A) is entirely in contact with the skin, the skin colour/device-is-
ready LED (5C) starts to flash slowly.
10. Press the pulse activation button (2). The device immediately verifies the
skin colour: if the colour is light enough for safe application, the device emits
the light pulse on the skin accompanied by a sound, and the skin colour/
device-is-ready LED (5C) goes off. A slight tingling sensation may be felt.
Note: if the appliance does not emit a light pulse and the skin colour/
device-is-ready LED (5C) flashes rapidly, the skin tone is too dark for
safe application. Try to use the appliance on another part of the body.
11. Remove the treatment surface (1A) from the treated area.
12. A few seconds (depending on the power level set) after the previous
pulse is emitted, the skin colour/device-is-ready LED (5C) goes on again.
13. Select the application mode to continue the treatment.
80
By pulse Method
14A.Move the treatment surface (1A) to another section. Use the pressure
marks left previously to place the treatment surface on the adjacent section,
avoiding overlapped pulses (See "Covering the entire treatment area").
15A.Repeat the process, starting from point 8, until the entire area to be
treated is covered.
Sliding Method
14B.Keep the pulse activation button (2) pressed and slide the device in a
slow gliding motion while remaining in contact with the skin, along the
area to be treated.
At lower power levels (1 and 2), the device takes only 1 to 1.5 seconds to
recharge between one pulse and another, thereby allowing an uninterrupted
sequence of flashes.
Make sure the entire area you intend to treat is covered while avoiding
to go over the same area a number of timed during the same session.
AFTER TREATMENT
16. Press the power level setting and on/off button (5A): all the LEDs will
flash sequentially.
17. Remember the power level used for the treatment session as this will be
reset when the appliance is next switched on.
18. Disconnect the adaptor cable (7) from the socket.
Caring for the skin after the hair removal session.
See "Other precautions for safe use".