1A
1 - Press call button n.3 (position 1A)
to set the number of buttons used (3)
on the audio/video panel.
Wait for audible confirmation (*).
2 - Press the same button again to set
the total number of user calls in the
block (3).
Wait for audible confirmation (*).
EXAMPLE 2 - X2
block
featuring
Targha audio-only entry panel with 10
calls and additional pushbutton
panels (fig. 6).
2B
1B
1 - Press call button n.4 (position 1B)
to set the number of buttons used (4)
on the audio/video panel.
Wait for audible confirmation (*).
2 - Then press call button n.10 (posi-
tion 2B) to set the total number of user
calls in the block (10).
Wait for audible confirmation (*).
EXAMPLE 3 - X2
block
featuring
Targha entry panel with camera with
12 calls and additional pushbutton
panels (fig. 7).
1C
2C
1 - Press call button n.1 (position 1C)
to set the number of buttons used (0)
on the audio/video panel.
Wait for audible confirmation (*).
2 - Then press call button n.12 (posi-
tion 2C) to set the total number of user
calls in the block (12).
Wait for audible confirmation (*).
EXAMPLE 4 - X2
block
featuring
entry panel with AZ/304 or AZV/304
with 2 calls, with no additional push-
button panels (fig. 8).
1D
5
1 - Press call button n.2 (position 1D)
to set the number of buttons used (2)
on the audio/video panel.
Wait for audible confirmation (*).
2 - Press the same button again to set
the total number of user calls in the
block (2).
Wait for audible confirmation (*).
EXAMPLE 5 - X2
block
entry panel with AZ/304 or AZV/304
with 10 calls and additional pushbut-
ton panels using module VZS/308C
(fig. 9).
1E
6
1 - Press call button n.4 (position 1E)
to set the number of buttons used (4)
on the audio/video panel.
Wait for audible confirmation (*).
2 - Then press call button n.10 (posi-
tion 2E) to set the total number of user
calls used (10).
Wait for audible confirmation (*).
WARNING. If there is a porter swit-
chboard in the system, the first
button is allocated as the porter
call button.
EXAMPLE 6 - X2
block
digital Targha entry panel with came-
ra with 20 calls (fig. 10).
1
2
3
4
5
6
7
8
9
0
C
P
S
T
4
C
1-2
7
2
0
3
1 - Press 4 and
(if using the porter
call P, press 3 and
).
Wait for audible confirmation (*).
2 - Press C to delete the number
displayed.
3 - Enter 20 and press
total number of user calls in the block
(20).
Wait for audible confirmation (*).
(*) Type of audible confirmation
Audible confirmation consists in an
audible call signal and a double audible
signal with the solenoid door lock
release command being activated.
3 - EXITING PROGRAMMING
AND AUTOMATIC
PROGRAMMING
OF IPD/300LR AND
IOD/303LR UNITS,
WHERE APPLICABLE
If an IPD/300LR porter switchboard
8
or IOD/300LR accessories are instal-
led in the system, they will be detec-
ted automatically when you exit pro-
gramming (whether programming
receivers or entry panels).
In installations with no system 300 or
X2 entry panels, you will need to
enter and exit programming mode to
program an IPD/300LR unit.
Every time you exit programming, the
yellow LED lights for approx. 1 s to
featuring
indicate that the automatic program-
ming operation has been completed.
The LED goes off to tell you that you
have exited programming.
4 - PROGRAMMING
SLAVE X2
ENTRY PANELS
This procedure must be performed
once you have programmed the units
described in point 2.
2E
4.1 - Start with the block's Master
entry panel.
4.2 - Remove the SW1 jumper from
the X2 block Master entry panel (the
one connected to the XA/300LR
power supplier).
4.3 - Wait for the audible signal confir-
ming the operation.
9
The number of notes equals the total
number of X2 entry panels connected
to the block (you may have to wait 3 to
15 s for audible confirmation).
4.4 - Refit jumper SW1.
5 - CHANGING
THE DEFAULT USER
PROGRAMMING DEVICE
The device for programming the recei-
vers can be chosen before entering
programming mode with the receiver.
WARNING. The user programming
device can only be changed once
you have programmed the entry
panels
(chapter
featuring
IPD/300LR switchboard (chapter 3).
Proceed as follows:
5.1 - Enter
receiver
mode.
- From the system 300 entry panel you
plan to use for programming, make a
call to any of the receivers (a note
sounds to confirm the operation).
- If you want to use the IPD/300LR
porter switchboard instead, make any
)
call (e.g. 1 +
key F1 (a note sounds to confirm the
operation).
5.2 - Start receiver programming, star-
ting from point 1.2.
10
WARNING. The programming pro-
cedure for the VSE/300 selector,
where fitted, must only be perfor-
med once you have programmed
which calls from the entry panels
are to be associated with which
receivers.
to set the
NOTE. Once the power supplier
has been programmed using the
PCS/300 or MPP/300LR unit, the
entry panels' standard program-
ming is no longer accessible.
To restore default conditions, plea-
se refer to the related chapter.
6 - RESTORING
DEFAULT CONDITIONS
6.1 - Enter
mode;
the LED flashes.
6.2 - Press the SERVICE button for at
least 15 s;
the LED goes off.
7 - SELFTEST
This facility can be used to run checks
on the system installed, checking
audio and video channels for correct
connections, and making sure LON
devices (entry panels, porter switch-
boards etc.) are working properly.
7.1 - To enter selftest mode, press the
SERVICE button for about 1 s twice in
a row (maximum 3 s between 1st and
2nd time it is pressed).
The LED remains lit for an extended
period and there is a short pause to tell
you that the operation has been perfor-
med.
7.2 - Press
quickly to exit selftest mode.
The LED goes off.
Contact BPT's Technical Support for
information on using this facility.
FUNCTION OF YELLOW LED
- The LED flashes regularly: receiver
programming mode on.
- LED on with short interruptions:
selftest mode on.
- LED on: entry panel programming on
or malfunctioning.
- LED off: normal operation.
MALFUNCTIONING
DUE TO INCORRECT
PROGRAMMING
1 - Picture distorted or with poor
contrast:
- entry panels not programmed;
- video twisted pair polarity inverted;
- HAV/200 jumper position incorrect (T
position incorrect).
2 - Audio problems (whistling, volu-
me low):
- entry panels not programmed;
- one of wires in audio twisted pair has
not been connected;
2)
and/or
- entry panel volume control needs
adjusting.
Function of each terminal, figure 1
programming
Terminal block A
L
mains
N
Terminal block B
L LON data line
+
18 V DC; power supply
then press function
entry panel
A audio from entry panel
Terminal block C
audio entry system line
B
18V DC 0.2A
+
18 V DC power supply
monitors centralized
SW2 jumper operation (fig.1)
This is usually inserted to allow an
increase in X2 line data receiver sensi-
bility.
RJ45 socket (fig. 1)
Used for connection to programming
device (IPC/300LR or MPP/300LR).
receiver
programming
the
SERVICE
button
3