Difference mode dIF
This mode refers to the infrared temperature and calculates the difference between the
maximum and minimum infrared temperature while measuring. The value is deleted
and calculated again at the start of a new measurement or by pressing the trigger (9).
!
Difference mode dIF enables fast assessment with the aid of the maximum temperature difference
within a structural element, e.g. house door / window / masonry.
15
Contact temperature mode T-K (K-type)
The device automatically switches to contact temperature mode T-K as soon
as a temperature sensor (K-type) is connected. With a minimum battery charge
of 15%, the device does not switch off automatically while the temperature
sensor remains connected.
MIN value display
3 sec
!
The Min/Max values are deleted when switching modes and when the device is switched on/off.
16
Dry-bulb temperature dbu
17
Wet-bulb temperature Wbu
CondenseSpot XP
MAX value display
SET
3 sec
18

Memory function

The device is has 50 storage locations.
Save
An acoustic signals confirms successful storage.
The Save function is not available in HEAT
!
mode. In contact temperature mode the
measured value will be stored only if it
is selected.