Controls And Indicators; Inspections Prior To Starting; Starting And Stopping - Blastrac BDC1330 DBP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating manual BDC1330 DBP/LPP

Controls and indicators

1.
Start/stop switch
(Only EU version)
2-way selector:
position "0" - The vacuum cleaner is turned OFF.
position "I" - The vacuum cleaner is turned ON.
2.
Main motor Start/Stop indicator and button
If the indicator is lit, the main motor is ON.
You can start/stop the main motor with this button.
3.
Second motor Start/Stop indicator and button
If the indicator is lit, the second motor is ON.
You can start/stop the second motor with this button.
4.
Third motor Start/Stop indicator and button
If the indicator is lit, the third motor is ON.
You can start/stop the third motor with this button.
5.
Stop button
This button stops all the motors simultaneously when
pressed (but doesn't turn the power of the vacuum
cleaner off).
6.
Low compressor pressure alarm indicator
If lit, this indicates an anomaly in the pressure of the
compressor.
7.
Max. vacuumed level indicator
If lit, this indicates the maximum level of the vacuumed
material has been reached in the container, if the level
control for solids is installed.
8.
Power indicator
Indicates the vacuum cleaner is powered.
9.
Primary filter indicator
Green - Indicates the cartridge filters are functioning
properly.
Red - Indicates the cartridge filters are blocked.
10.
Absolute filter indicator (if installed)
Red - Indicates the absolute filter is blocked.
1.
Dust container release lever
2.
Castor lever
3.
Closing band lever
4.
Electric power cable
5.
Handle
GB
6.
Inlet
7.
Electrical panel
Figure 4
Figure 5

Inspections prior to starting

Prior to starting, check that:
the filters are installed;
all the levers are locked in place;
the vacuum hose and tools have been correctly fitted to
the inlet (6 - Fig. 5);
the bag is installed, if applicable.
WARNING!
Do not use the vacuum cleaner if the filter is faulty.

Starting and stopping

WARNING!
Before starting the vacuum cleaner, lock the castor
brakes (2 - Fig. 5) and turn the switch (7 - Fig. 5)
on "I" position.
WARNING!
Check the pressure of the air used to clean the
filters which is produced by the compressor.
It must never be superior than 5,5 bars, if
necessary, adjust it to the correct level using the
related pressure governors.
Figure 4 (EU version)
Turn switch (1) to position "I" to start the vacuum
cleaner.
When the switch is in position "I" the motors start
in sequence and the state of the same is shown by
indicators (2-3-4).
Turn the switch to position "0" to stop the vacuum
cleaner.
Figure 4 (US version)
To turn on the vacuum cleaner, press the switches (2-
3-4).
When pressed, the motors start and the state of the
same is shown by indicators (2-3-4).
To turn off the vacuum cleaner, press the switches
again.
8/14
info@blastrac.eu

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bdc1330 lpp

Tabla de contenido