SPECIFICATIONS
Type of power
Air pressure (Gauge)
Applicable staples
Amount of loadable staples
Size
Weight
Hose (inside diam.)
STAPLE SELECTION
Choose a suitable staple from Fig. Staples which are not
shown in Fig. can not be driven with this tool.
16 Gauge
Min.
1.45mm
7.9mm
(.057")
(.309")
Dimension of staples
STANDARD ACCESSORIES
(1) Hexagon bar wrench for M5 screw ........................... 1
(2) Eye protection ............................................................. 1
(3) Oiler ............................................................................. 1
OPTIONAL ACCESSORY
Sequential Trip Mechanism Kit (Code No.876762)
(Sequential Fire Parts Set, Single Shot Parts)
With the sequential fire parts, the staple is driven
only by squeezing the trigger after pushing down
the push lever.
By installing these parts, driving staples into
improper positions and unexpected firing of staples
caused by accidental operation of the push lever can
be prevented.
7
Piston reciprocating
4.9 – 8.3 bar (70 – 120 psi.)
ref. Fig.
150 staples
365 mm (L) × 258 mm (H) × 76 mm (W) (14-3/8" × 10-5/32" × 3")
2.0 kg (4.4 lbs)
6 mm (1/4")
7/16" Crown
Max.
APPLICATIONS
Construction work such as wall sheathing,
subflooring.
Mobile and modular home construction.
PREPARATION PRIOR TO OPERATION
1. Prepare the hose
Be sure to use the hose provided with minimum
6 mm (1/4") inside diameter.
NOTE:
The air supply hoses must have a minimum working
pressure rating of 12.8 bar (180 psi) or 150 percent of
the maximum pressure produced in the air supply
system, whichever is higher.
2. Check on safety
CAUTIONS:
Unauthorized persons (including children) must be
kept away from the equipment.
Wear eye protection.
Check the retaining screws which fix the exhaust
cover, etc. for tightness.
Check the stapler for air leaks and defective or rusty
parts.
Check whether or not the push lever works correctly.
Also check whether or not any dirt has adhered to the
moving parts of the push lever.
Recheck on operational safety.
BEFORE USE
1. Check the air pressure
CAUTION:
The air pressure must be constantly maintained at 4.9
– 8.3 bar (70 – 120 psi.).
Adjust the air pressure between 4.9 to 8.3 bar (70 –
120 psi.) according to the diameters and length of
staples and hardness of the wood being stapled. Pay
special attention to the output pressure, capacity, and
piping on the air compressor, so that air pressure does
not exceed the specified limit. Note that excessive
pressure may affect overall performance, service life,
and safety.
2. Lubrication
(1) Prior to operating this stapler, be sure to provide an
air set between the air compressor and this device.
Lubrication through the air set offers smooth
operation, extended service life, and anticorrosion.
Adjust the oiler so that a single drop of oil is supplied
at intervals of 5 to 10 stapling cycles.