Return To Cembre For Overhaul - Cembre CP1086-W-1000-KV Manual De Uso

Unidades de corte aisladas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

– To remove any deposits in the oil circuit, the flexible insulated hose must be disconnected from
the pump. Operate the oil discharge pedal and at the same time press the main pedal twice. In
this way the pump oil ducts are cleaned.
– Change the oil at the maintenance intervals, registering the date the oil is changed.
For this purpose the cable cutting units must be sent, complete, to Cembre or to personnel
authorised by Cembre.
Cembre will change the oil and at the same time carry out an "Inspection".
– Damaged parts can only be replaced by original Cembre spare parts.
– Substitution of individual parts can only be carried out by personnel authorised by Cembre.
– To exclude hidden faults following maintenance or repairs on the cable cutting units, these
operations must be carried out by Cembre or by personnel authorised by Cembre.
– For all maintenance and repairs carried out on the cable cutting units, the person who carried
them out is responsible. If changes to the product are made so that it is no longer identical to
the certified finished product (e.g. failure to use original spare parts), the authorisation to use the
GS trademark shall be lost.
– Cembre recommends having maintenance carried out by trained personnel.
Maintenance must be carried out at the following intervals:
6 years – occasional use - example: about 6 times a year.
4 years – normal use - example: about 12 times a year.
2 years – frequent use - example: more than once a month during the year.
Caution: Maintenance carried out by trained personnel is, according to BGVA 3, absolutely neces-
sary at the latest aafter 6 years disregarding the frequency of use.
– To replace the hydraulic hoses follow the instructions of BG nr. BGR 237 regulation.
In the case of disposal, the device with its contents (insulating hydraulic oil) must be dealt with
only in accordance with local regulations.

9. RETURN TO Cembre FOR OVERHAUL

In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certificate supplied by Cembre together with the tool or fill in and attach
the form available in the "ASSISTANCE" section of the Cembre website.
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp1096-w-1000-kvCp1120-w-1000-kv

Tabla de contenido