Figure 6
Figure 7
Sensor
Incorrect
Figure 8
Sensor sees beyond
label (Will not stop)
Sensor sees front edge of label
Figure 9
PAGE 3 OF 9
ADJUSTMENTS
Brush Wing
Screw
Wing Screw
Sensor sees strip plate
(Will not feed)
Power Switch
1. To apply the proper amount of tension for proper
label feeding and detection, loosen brush wing
screw and press down to increase tension, then
tighten screw. (See Figure 6)
2. Loosen wing screw, then adjust sensor plate.
3. Point sensor toward the top edge of the label; then,
tighten wing screw to secure sensor in place.
(See Figures 7 and 8)
4. Connect power cord and press power switch to turn
on. (See Figure 9)
1-800-295-5510
uline.com
0821 IH-7206