Operation
Setting Interface: RS-232 and TCP/IP Settings.
The default communication mode is the RJ45 Ethernet port. Users can configure the communication mode through the RS-
232 and Net Setting boxes. Click "OK" in the corresponding box to set the desired communication mode, then click "Connect"
to connect. The status bar should change, as shown below.
RS-232 Setting
To control the switch using RS-232 commands, ensure the following communication parameters are set: 9600 bps, 1 start
bit, 1 end bit, no check bit. Set the data format as ASCII and open the serial port.
Net Setting
The B302-4HX4H-4K and B302-8HX8H-4K come with a pre-assigned static IP address. They can be accessed remotely by
configuring your network to match the pre-assigned IP address style. Simply connect a user-supplied RJ45 cable between the
matrix switch and your target computer, and then configure your network settings (IPv4) accordingly.
Note: The pre-assigned IP address will never change even if you disconnect and reconnect the target computer.