APPLICATION
When specific power and terminal configurations exist and
additional door protection is required, the LC-36A Light Curtain
can be installed on non-monitored operators from manufacturers
other than LiftMaster by following these instructions.
Although this procedure has been tested with some operators,
LiftMaster does not guarantee this method will work with all
operators.
REQUIREMENTS
• LiftMaster CPICARD
• LiftMaster CPS-OPEN4 Photoelectric sensors
For installs with existing photoelectric sensors, they MUST be
replaced with LiftMaster CPS-OPEN4 photoelectric sensors. NO
OTHER PHOTOELECTRIC SENSORS ARE RECOMMENDED FOR
THIS APPLICATION.
• LiftMaster 100MAPS External Power Supply (Optional)
If power is not available from the operator, the 100MAPS can
supply the required voltage to the CPICARD.
The operator must have the following functions:
• 24VAC or 24VDC power output terminals and at least 40mA of
output available to operate the LC-36A Light Curtain in addition
to the power required to operate the CPS-OPEN4 photoelectric
sensors (see CPS-OPEN4 manual for more information).
NOTE: The LiftMaster 100MAPS External Power Supply can be
used to power the CPICARD instead of the 24VAC or 24VDC
output terminals on the operator.
• Non-monitored edge terminal and common terminal
LiftMaster CPICARD
LiftMaster CPS-OPEN4
photoelectric sensors
INSTALLATION
Mount the LC-36A light curtain and CPS-OPEN4 photoelectric sensors as instructed in their respective manuals. Follow the wiring
instructions on the next page.
LiftMaster 100MAPS
external power supply
(optional)
1
LC-36A ADDENDUM
INSTALLING THE LC-36A LIGHT CURTAIN
ON NON-MONITORED OPERATORS
To prevent possible SERIOUS INJURY or DEATH from a
closing door:
• Be sure to DISCONNECT POWER to the operator BEFORE
installing the Light Curtain.
• The door MUST be in the fully opened or closed position
BEFORE installing the Light Curtain.
• Correctly connect and align the Light Curtain transmitter
and receiver.
• The Light Curtain is for use with LiftMaster
Door Operators. Use with ANY other product voids the
warranty.
• DO NOT use this product for the protection of dangerous
machinery or in explosive atmospheres or radioactive
environments. Use ONLY specific and approved types of
devices for such applications.
• The Light Curtain MUST be installed ONLY by authorized
and fully trained personnel.
• Installing the Light Curtain according to these instructions
does NOT make an operator UL 325 compliant.
To prevent possible product damage and incorrect operation:
• NEVER scratch or paint the optical sensors.
• DO NOT drill any additional holes into the Light Curtain.
• Correctly connect and align the Light Curtain transmitter
and receiver.
• DO NOT bend or twist the Light Curtain.
• Oil may damage the Light Curtain cable so contamination
MUST be avoided at ALL times.
• DO NOT mount the Light Curtain where sunlight or other
external infrared light sources will shine directly into the
optical sensors of the Light Curtain receiver. If necessary,
switch the mounting side of the Light Curtain transmitter
and receiver.
Installation and service information are available.
Call our TOLL FREE number:
1-800-528-2806
LiftMaster.com
®
Commercial

Publicidad

loading

Resumen de contenidos para LiftMaster LC-36A

  • Página 1 Installation and service information are available. Call our TOLL FREE number: LiftMaster CPS-OPEN4 1-800-528-2806 photoelectric sensors LiftMaster.com INSTALLATION Mount the LC-36A light curtain and CPS-OPEN4 photoelectric sensors as instructed in their respective manuals. Follow the wiring instructions on the next page.
  • Página 2 WIRING The LiftMaster CPICARD is used to connect the LC-36A and CPS-OPEN4 to a non-monitored operator. The CPICARD separates the incoming and outgoing logic, minimizing interference. The CPICARD accepts both pulsed and normally open contact devices which appear to the operator as normally open devices.
  • Página 3 MORTELLES lorsqu’une porte de garage se ferme : est exigée pour la porte, le rideau de lumière LC-36A peut être • S’assurer de DÉBRANCHER L’ALIMENTATION à l’actionneur installé sur des actionneurs non surveillés de fabricants autres AVANT d’installer le rideau de lumière.
  • Página 4 CÂBLAGE La CPICARD de LiftMaster est utilisée pour connecter le rideau LC-36A et les capteurs CPS-OPEN4 à un actionneur non surveillé. La CPICARD sépare la logique entrante et sortante, minimisant ainsi l’interférence. La CPICARD accepte les dispositifs à impulsions et à...
  • Página 5: Instalación

    Llame a nuestro NÚMERO GRATUITO: 1-800-528-2806 Sensores fotoeléctricos CPS-OPEN4 LiftMaster LiftMaster.com INSTALACIÓN Instale la cortina de luz LC-36A y los sensores fotoeléctricos CPS-OPEN4 tal como se indica en los respectivos manuales. Siga las instrucciones de cableado en la página siguiente.
  • Página 6 CABLEADO La CPICARD LiftMaster se usa para conectar la LC-36A y los CPS-OPEN4 a un operador no monitoreado. La CPICARD separa la lógica entrante de la saliente, minimizando la interferencia. La CPICARD acepta dispositivos de contacto pulsado y normalmente abierto que aparecen ante el operador como dispositivos normalmente abiertos.
  • Página 8 © 2016, LiftMaster All Rights Reserved Tous droits réservés 01-39018 Todos los Derechos Reservados...