Specifications - Mitsubishi Electric Mr SLIM PKA-A KA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11. Troubleshooting
Having trouble?
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
controller is close.
The operation lamp near the receiver for the wireless remote controller
on the indoor unit is flashing.

12. Specifications

Model
Power source (voltage <V>/Frequency <Hz>)
Rated Input (Indoor only)
Rated Current (Indoor only)
Heater
Dimension (Height)
Dimension (Width)
Dimension (Depth)
Fan airflow volume (Low-Middle-High)
Noise leve (Low-Middle-High)
Net weight
All manuals and user guides at all-guides.com
PKA-A24KA(L)
<kW>
0.05
<A>
0.36
<kW>
<inch>
<inch>
<inch>
<CFM>
<dB>
<lbs>
Here is the solution. (Unit is operating normally.)
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in an echo-free room.
High sound-
absorbing rooms
Location
Broadcasting
examples
studio, music
room, etc.
Noise levels
3 to 7 dB
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure
that the batteries are installed in the correct directions (+, –).
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be
sure to provide the dealer with the model name.
PKA-A30KA(L)
Single 208/230, 60
0.05
0.36
14-3/8
46-1/16
11-5/8
635-705-775
39-42-45
46
Normal rooms
Low sound-
absorbing rooms
Reception room,
Office, hotel
hotel lobby, etc.
room
6 to 10 dB
9 to 13 dB
PKA-A36KA(L)
0.08
0.57
705-810-920
43-46-49
17

Publicidad

Tabla de contenido
loading

Tabla de contenido