No change in measurements if connected with
drain illustrated. (K-7272)
60-1/4" (1530 mm) Max
1
17-1/2"
(445 mm)
Product Information
Applicable product:
5' (1.5 m) bath – left-hand drain
5' (1.5 m) bath – left-hand drain with grab
bar in color CP
5' (1.5 m) bath – right-hand drain
5' (1.5 m) bath – right-hand drain with grab
bar in color CP
Fixture*:
Bathing well:
Basin area, bottom
43" (1092 mm) x 22-1/2" (572 mm)
Basin area, top
48-3/4" (1238 mm) x 23-3/8" (594 mm)
Weight
260 lbs (117 kg)
To overflow:
Water depth
14" (406 mm) seated
Capacity
72 gal (273 L) without a bather
* Approximate measurements for comparison only.
1128532-1-E
2
16"
(406 mm)
3
Door
19"
(483 mm)
Lowered
K-1913-L
K-1913-LB
K-1913-R
K-1913-RB
60-1/4" (1530 mm) Min
7-5/8" (194 mm)
3-7/8" (98 mm)
(LH)
Drain Cutout
10" (254 mm)
24-1/2"
16"
(622 mm)
(406 mm)
Front Edge of
Drip Tray
39-1/4"
34"
(997 mm)
(864 mm)
38"
Raised
(965 mm)
Required Electrical Service
120 V circuit required. Locate a Class A Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD)
outlet within 36" (914 mm) of the door/system controller.
Door/System Controller
Notes
Install this product according to the installation guide.
Floor support under the bath must provide for a minimum of 60
lbs/square foot (293 kg/square meter) loading.
Hot water supply should be 70% of capacity or greater.
Installations will vary.Three drains are required. Drains 1 and 2
require a 10" (254 mm) x 10" (254 mm) cutout. Drain 3 requires a
10" (254 mm) x 10" (254 mm) cutout if accessible from below. For
above-floor access, make a 10" (254 mm) x 16" (406 mm) cutout.
Support the finished floor accordingly.
A 350 VA size or greater Uninterruptible Power Supply (UPS) is
recommended for areas of routine or prolonged power outages.
Will comply with ADA when installed per Section 607 Bathtubs of
the Act.
Fixture conforms to ANSI Standard Z124.1.2. All dimensions are
nominal.
2
Three drain cutouts required.
10"
(254 mm)
30" (762 mm)
3-1/2"
1
2
(89 mm)
Drain
Cutout
3
5-1/2"
(140 mm)
10" (254 mm)
33-1/2" (851 mm)
1/4" (6 mm)
1-1/2" OD
32-1/2"
(826 mm)
24-1/2"
(622 mm)
33-1/2"
(851 mm)
Min
Drain Cutout
1-1/4"
(32 mm)
Subfloor
120 V, 500 mA, 60 Hz
Kohler Co.