UPS 600VA – User's Manual
Safety & proper usage reminders (Safety & proper usage reminders)
-
When connected to mains power, the UPS needs to be On for its battery to charge.
-
Do not open or repair this device, and keep it away from liquids.
-
If the battery is opened or damaged, the substances released may be flammable and harmful to
skin, eyes.
-
Always connect the UPS to an earthed wall socket.
-
Do not connect a multiple socket to the UPS.
-
The output ports may still be powered, even when the device is turned off.
-
Make sure the device is not placed on a heat-sensitive surface and that the UPS has sufficient
ventilation.
Troubleshooting (Troubleshooting)
Indication
Yellow LED steady
Reason: The battery is charging.
No beeps
Action: No action required.
Reason: The battery is fully charged, and the UPS is functioning
Yellow and green LEDS steady
normally.
No beeps
Action: No action required
Reason: The UPS is not powered (power outage)
Red LED flashing
The UPS is powering the connected devices with its battery.
1 beep every 5 seconds
Action: Save your documents and shut down the computer.
Reason: The UPS is not powered (power outage).
Red LED steady
The battery will be empty within 2 minutes.
2 beeps every second
Action: Save your documents and shut down the computer urgently.
Red LED steady
Reason: The UPS is overloaded.
4 beeps every 2 seconds
Action: Disconnect some devices from the UPS output ports.
Red LED steady
Reason: The UPS is in short circuit.
Continuous beeping
Action: Check each of the connected devices to identify the faulty one.
Reason: The battery is discharged, or the fuse needs replacing.
No LEDs
Action: Connect the UPS to a power source, or replace the fuse.
No beeps
Reason and Action
3