Important! The fitting must be installed, flushed
and tested after the valid norms!
Assembly
1
Flush through the supply pipes.
2
Fasten the mixer with the washers.
The hot and cold supplies must be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
32420000: The flow is changed from bath to
shower function by pulling the knob at the upper
side of the spout. After shutting off the water
flow, the mixer returns automatically to the bath
function.
Technical Data
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
Connections
Connections
Rate of flow:
anti-pollution function
Test certificate
DVGW
33163000
4
max. 1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
153 mm
cold right - hot left
G ¾"
G ½"
ca. 20 l/min 0,3 MPa
P-IX
SVGW
X
English
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
To adjust the hot water limiter on single lever
mixers, please see page 6.
No adjustment is necessary when using a
continuous flow water heater.
Important!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Spare parts see page 3
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
locking screw for handle
6
aerator
7
selector assy
8
diverter knob
9
non return valve DW 15 (10)
10
hose connection
ACS
NF
WRAS
33092000
96338000
96656000
96690000
92730000
96059000
13956000
94077000
96466000
94074000
96044000
KIWA