3
Basic operation
Event
Device analyses shock
3.6
Start recording direct via MLog IM50
Function
Start
press ON button lon-
recording
ger than 4 seconds
3.7
Battery replacement (MLog IM50 and IM100)
Function
Announce battery
replacement
Abort / conclude
battery replacement
3.8
Set user marker (MLog IM50 and IM100)
Function: set user marker
Action
Press „OFF" button
and hold and than
briefly press „ON"
button
24
LED EVENT/ALARM (red)
Action
ACTIVE
(green)
off
Action
press OFF button longer
than 4 seconds
press OFF button longer
than 4 seconds
LED
EVENT/ALARM (red)
lights 2 seconds
1x flashing
LED
EVENT/
ALARM (red)
No recording is in progress and
off
memory is empty
LED
BATTERY
(yellow)
The event is recorded in the Log Book;
the device continues to record data and
recognizes the exceeding of limit values;
GPS, GSM and bluetooth are deactivated in
the meantime;
the display of the IM100 is inactive;
lights
during the next 30 minutes the batteries can
permanent
be replaced .
Note that when replacing the battery, the
USB cable must be disconnected from the
computer. This ensures that the prognosis
of the remaining battery runtime is working
correctly.
GPS, GSM and bluetooth are again activated,
goes out
provided the battery status is sufficient
A new event with time stamp is recorded in the Log Book .
The next marker can be set as soon as the red LED is off
again .
Precondition
Note
Result
BA3431002/04 ES-EN