Switch location of receiver unit
All
/NORMAL selector switch
Set this switch to the "NORMAL" position for the normal operation of the air conditioner. When this
switch is set to the "ALL
RCU:SUB/RCU:MAIN selector switch
Set this switch to the "RCU:MAIN" position for normal operation. Refer to page 7 for setting to the
"RCU:SUB" position.
PCB CHK switch
This switch is not used and should be set in the position shown in the figure.
TEST RUN switch
This switch is used for test running.
Installation location of receiver unit
• Do not install in a location where the air contains oil mist, such as in a kitchen or factory.
• Do not install next to a window, or in any other location directly exposed to sunlight and outside air.
• Do not install nearby devices which can be expected to produce electrical noise, such as elevators,
automatic doors, and industrial sewing machines.
• If the receiver unit is installed near a rapid-start type or inverter-type fluorescent lamp (a lamp which
does not include a glow lamp), it may not be possible to receive the wireless remote controller signal
in some cases. In order to prevent interference from fluorescent lamps, leave a minimum of 2 meters
between the receiver unit and the fluorescent lamps, and install the receiver unit in a location where it
can receive the wireless remote controller signal when the fluorescent lamps are lit.
Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807
All manuals and user guides at all-guides.com
" position, the indoor unit of the air conditioner is turned off.
2
Address selector switch
This switch is used to address
one of a maximum of six air con-
ditioners that can be controlled by
the remote controller.