CLEANING AND MAINTENANCE

After each use, turn off the power and unplug the unit. Let it to cool before
cleaning.
Warning: Never immerse the unit or its cord in water or other liquids.
Danger of electric shock.
Wipe the cooktop surface with a soft cloth. If necessary, you can use a cleaner
specific to induction hobs.
Warning: Never use abrasive or flammable cleaners to clean the cooktop.
Store the appliance in a dry place.
FAILURES AND SOLUTIONS
Failures
After
connecting
the unit and
pressing the
on/off button,
the plate does
not react.
The plate
stops during
use and a
beep is
emitted.
No possibility
to use the
functions
during
operation.
Displaying
error codes
Check points
Is there a power failure?
Did the fuses break?
Is the appliance plugged
into a working outlet?
Is the utensil used
compatible with an
induction cooker?
Is the utensil properly
centered on the cooking
area?
Is the utensil suddenly
removed from the hob?
Is the utensil empty or is
the temperature too high?
Is the fan grill obstructed?
Has the cooktop been
running for more than 2
hours without instructions?
E0: no utensil or cooking
utensil not suitable for
induction hobs
E1: IGBT sensor
open/short circuit
Solutions
Reconnect after power is
restored.
Check the causes of the power
outage.
If the problem persists, contact
the distributor's after-sales
service.
Use an utensil that is suitable for
induction hobs.
Centre the utensil on the
cooking area without removing
it.
.
Check that the utensil is being
used correctly.
Remove anything that may be
obstructing the fan grill.
Reset the cooking mode or
timer.
The plate will operate again as
soon as it has cooled down.
If error signals E0, E2 and E6
are displayed, check whether the
cookware is suitable for
induction hobs or restart the
appliance after it has cooled
down naturally.