Ferroli FORCE W 60 Instrucciones De Uso, Instalación Y Mantenimiento página 219

Ocultar thumbs Ver también para FORCE W 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72
FORCE W
Heating temperature reduction
Access the "Reduction Adjustment Temp" menu to
vary the temperature from a minimum of 0°C to a max-
imum of 50°. Confirm with the OK button.
This parameter is used only if time program-
A
ming is activated. See "Time programming"
on page 219
DHW temperature adjustment (with optional hot water tank installed)
Access the "Adjustment Temp" menu to vary the
temperature from a minimum of 10°C to a maximum of
65°C. Confirm with the OK button.
The boiler comes with the time
B
program not activated. Therefore,
if requested, this is the setpoint
value.
DHW temperature reduction (with optional hot water tank installed)
Access the "Reduction Adjustment Temp" menu to
vary the temperature from a minimum of 0°C to a max-
imum of 50°C. Confirm with the OK button.
This parameter is used only if time program-
A
ming is activated. See "Time programming"
on page 219
Time programming
Time programming is done in the same way both for heating and for DHW; the two programs are independent.
To program Heating, access the "Time Program" menu by following the path "USER MENU
Program".
To program DHW, access the "Time Program" menu by following the path "USER MENU
TER"
"Time Program".
Choose the type of programming to carry out and follow that described below.
EN
fig. 14
cod. 3541V232 - Rev 00 - 08/2021
CH setpoint reduction
35
to confirm
CH setpoint
65
to confirm
fig. 15
DHW setpoint reduction
25
to confirm
fig. 16
"HEATING"
"DOMESTIC HOT WA-
"Time
219