3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted as a flushmount
on a regular (no-slope) ceiling only. Downrod
installations are not available for this fan.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Mounting Plate Installation.
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and
can support the full weight of the fan. Ensure the outlet box is
clearly marked "Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do so can
result in serious injury.
CAUTION: Be sure outlet box is grounded properly and that
a ground wire (GREEN or bare) is present.
Install mounting plate to outlet box using original screws,
spring washers and flat washers provided with new or
original outlet box. *Pull electrical wiring from outlet box
through center hole in mounting plate.
*Note: It is very important that you use the proper hardware
when installing the mounting plate as this will support the
fan.
All manuals and user guides at all-guides.com
page 3
blade edge
30
inches
7 feet
(76cm)
(2.13m)
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
mounting plate
flat washers
spring washers
outlet box screws
12ft. - 20ft.
(3.66m - 6.1m)
downrod
installation