Cleaning And Maintenance - MCS Master BLP33ET Manual Del Usuario

Ocultar thumbs Ver también para BLP33ET:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
►►8. HEAT CAPACITY
en
REGULATION
it
Depending on the type of generator, the
appliance heat capacity can be regulated.
de
The heat capacity can be regulated by
es
acting on the knob positioned on the
fr
base of the generator (Fig. 22) or on
the pressure regulator installed on the
nl
gas cylinder (Fig. 23), depending on the
pt
model.
da
►►9. SWITCH-OFF FOR MANUAL
fi
MODELS (... / ...M / ...DV)
no
►9.1.Close the gas cylinder (Fig. 24).
►9.2.Leave the fan to cool for about 60
sv
s, in order to prevent internal damage
pl
due to overheating (generator internal
cooling).
ru
►9.3.Take the "O/I" switch to position "O"
cs
(Fig. 25).
hu
►9.4.Disconnect the generator from the
mains electricity (Fig. 26).
sl
►9.5.Disconnect the generator from the
tr
gas supply pipe (Fig. 27-28-29).
hr
►►10. SWITCH-OFF FOR
lt
ELECTRONIC MODELS (...E /
lv
...ET)
►10.1.Take the "O/I" switch to position
et
"O" (Fig. 25). The flame goes out and the
ro
generator performs the post-ventilation
sk
phase. Wait for the cycle to be completed
in order to prevent internal damage due
bg
to overheating (the phase is automatic
uk
and can last 50 s÷5 min depending on
the internal/external temperature at the
bs
generator).
el
►10.2.Close the gas cylinder (Fig. 24).
zh
►10.3.Disconnect the generator from
the mains electricity (Fig. 26).
►10.4.Disconnect the generator from
the gas supply pipe (Fig. 27-28-29).
All manuals and user guides at all-guides.com
N.B.: Do not disconnect the generator
from the mains electricity, before the
end of the post-ventilation phase, in
order to prevent internal damage due
to over-heating.
►►11. CLEANING AND
MAINTENANCE
Have the after-sales assistance check
correct functioning of the generator at
least once a year and/or as required. The
appliance must be cleaned before it is
put away after use.
►11.1.Before
maintenance, care and repairs of the
appliance,
sequence [Par. 9. "SWITCH-OFF FOR
MANUAL MODELS (... / ...M / ...DV)" or
"10. SWITCH-OFF FOR ELECTRONIC
MODELS (...E / ...ET)"].
►11.2.Cleaning only concerns the air
vent (rear side) of the generator.
►11.3.When the appliance is used
again, check the state of integrity of the
gas hose and power supply cable. If in
doubt regarding their integrity, request
the assistance of the technical after-sales
service.
►11.4.Do not carry out unauthorised
interventions.
►►12. ROOM THERMOSTAT
CONNECTION (...E / ...ET)
(optional)
Remove the plug connected to the
appliance
thermostat (optional) (Fig. 30).
See wiring diagram (...E / ...ET).
starting
any
carry
out
the
and
connect
the
type
of
switch-off
room

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Blp53etBlp73etBlp103et

Tabla de contenido